- 05000328/LER-1983-191-03, /03L-0:on 831227,rod C-11 Declared Inoperable Due to Erratic Behavior.Caused by Faulty Connection at Reactor Vessel Head.Low Current 500-volt Charge Placed on Cable. Rod Returned to Svc + (191)
- 05000416/LER-1983-191-03, /03L-0:on 831217,standby Fresh Air Unit a Placed in Isolated Mode to Meet Tech Spec Action Requirements Due to Planned Div 2 Electrical Outage on 831210.Caused by Operator Error.Procedures Revised + (191)
- 05000369/LER-1981-191-03, /03L-0:on 811215,while in Mod 5, Eight Unsuccessful Attempts Were Made from 811212-17 to Complete Diesel Generator 1B Run.Caused by Leaking Gasket Between Cooling Water Sys & Turbocharger Intercooler.Leak Repaired + (191)
- 05000369/LER-1981-191, Forwards LER 81-191/03L-0 + (191)
- 05000327/LER-1980-191-03, /03L-0:on 801124,component Cooling Water Pump C-S Motor Breaker Failed to Close,Rendering B Train Component Cooling Water Inoperable.Caused by Blown Fuse in Control Circuit.Fuse Replaced + (191)
- 05000327/LER-1980-191, Forwards LER 80-191/03L-0 + (191)
- 05000416/LER-1983-192-03, /03L-0:on 831223,first Shift Failed to Adequately Perform 12 H Channel Check of Tech Spec 4.3.7.1-1.7.Caused by Personnel Error.Daily Operating Log Being Revised + (192)
- 05000369/LER-1981-192-03, Circumferential Butt Welds on ASME Class 1 Piping Previously Identified as Flush Found Potentially Outside ASME Code Criteria.Const Procedures Will Be Revised to Define Profile for Flush Weld + (192)
- 05000369/LER-1981-192, Forwards Updated LER 81-192/03X-1.Detailed Event Analysis Encl + (192)
- 05000327/LER-1980-192-03, /03L-0:on 801201,F14 Control Bank B Rod Position Indicator Deviated by Greater than 12 Steps from Control Bank B Demand Counter.Caused by Shift in Calibr of Control Board Indicator.Indicator Recalibr & Returned to Svc + (192)
- 05000327/LER-1980-192, Forwards LER 80-192/03L-0 + (192)
- 05000416/LER-1983-193-03, /03L-0:on 831227,outboard Suction Valve Closed During Instrument Surveillance.Caused by Tip Breaking Off mini-test Clip.Surveillances Reviewed for Points Requiring Test Connections & Banana Jacks Installed + (193)
- 05000369/LER-1981-193, Forwards LER 81-193/03L-0.Detailed Event Analysis Encl + (193)
- 05000369/LER-1981-193-03, /03L-0:on 811224,technicians Initiated Low Steam Line Pressure Safety Injection Actuation on Both Trains. Caused by Procedural Deficiency.Procedure to Be Corrected by 820122 + (193)
- 05000327/LER-1980-193, Forwards LER 80-193/03L-0 + (193)
- 05000327/LER-1980-193-03, /03L-0:on 801208,review Identified That Channel Functional Test Instruction for Monitors Providing Automatic Termination of Release Did Not Adequately Demonstrate Automatic Isolation.Caused by Inadequate Instruction + (193)
- 05000369/LER-1981-194-03, /03L-0:on 811230,during Periodic Fire Pump Operability Test,Discovered That Fire Pump C Would Not Start.Cause Undetermined.Update Rept Will Be Submitted by 820226 + (194)
- 05000369/LER-1981-194, Forwards LER 81-194/03L-0 + (194)
- 05000327/LER-1980-194-03, /03L-0:on 801201,found Circuit Breaker 7 on 120-volt Vital Instrument Power Board 1-II Tripped,Rendering Radiation Monitors 1-RE-90-112/134/141 Inoperable.Caused by Failure of 0-RE-90-134 Motor.Motor Replaced + (194)
- 05000327/LER-1980-194, Forwards LER 80-194/03L-0 + (194)
- 05000327/LER-1980-195, Forwards LER 80-195/01T-0 + (195)
- 05000327/LER-1980-195-01, /01T-0:on 801212,util Notified That Interlocks on Emergency Feeder Breakers to 6.9-kV Shutdown Boards Could Allow Diesel Generators to Connect to Shutdown Boards W/O Operating Load Stripping Relays & Cause Generator Overload + (195)
- 05000327/LER-1980-196, Forwards LER 80-196/01T-0 + (196)
- 05000327/LER-1980-196-01, /01T-0:on 801211,during IE Bulletin 79-14 Review, Discovered Heat Transfer Cement Installed in Area of Pipe Hangers Could Restrict Relative Movement Between Pipe & Hanger.Error Made During Const.Cement Removed + (196)
- 05000327/LER-1980-197-01, /01T-0:on 801212,during Mode 5,notification Received That Solenoid Valves for Valve Operators on Six Containment Isolation Valves Not Qualified for Accident Environ.Affected Valves Replaced by Valves Qualified + (197)
- 05000327/LER-1980-197, Forwards LER 80-197/01T-0 + (197)
- 05000327/LER-1980-198, Forwards LER 80-198/03L-0 + (198)
- 05000327/LER-1980-198-03, /03L-0:on 801204,containment Hydrogen Analyzer 1-HZAN-43-210 Failed Weekly Functional Test (SI-640) When Checked w/4% Sample.Caused by Unauthorized Closure of Reagent Air Flow Rotameter.Analyzer Returned to Svc + (198)
- 05000327/LER-1980-199, Forwards LER 80-199/03L-0 + (199)
- 05000327/LER-1980-199-03, /03L-0:on 801209,high Steamflow Safeguard Program & Steam/Feedwater Flow Mismatch Bistable Found Set Above Tech Spec Values.Caused by Low Actual Differential Pressure Produced at Flow Transmitter.Setpoints Recalibr + (199)
- 05000327/LER-1980-200, Forwards LER 80-200/03L-0 + (200)
- 05000327/LER-1980-200-03, /03L-0:on 801217,valves 1-FCV-1-15,16 & 17 Found Not to Have Been Stroke Tested After Repacking on 801209. Caused by Engineer & Craft Failure to Notify Proper Personnel.Valves Tested & Personnel Instructed + (200)
- 05000327/LER-1980-201, Forwards LER 80-201/03L-0 + (201)
- 05000327/LER-1980-201-03, /03L-0:on 801216,diesel Generator 1A-A Failed to Start During Test on Diesel Generator 2A-A.Caused by Faulty Relay Flashed in Diesel Generator Control Circuit Resulting in Blown Fuse.Relay & Fuse Replaced + (201)
- 05000499/LER-2002-201, 0-001 for South Texas, Unit 2 Regarding Essential Cooling Water System Leak + (201)
- 05000327/LER-1980-202-03, /03L-0:on 801225,steamline Pressure & Flow Channel S/G-3 Train a Failed High & S/G-1,2 & 4 Train B Failed Low. Caused by Freezing of Unprotected Sense Lines.Lines Thawed. Design Changes Initiated + (202)
- 05000327/LER-1980-202, Forwards LER 80-202/03L-0 + (202)
- 05000327/LER-1980-203, Forwards LER 80-203/03L-0 + (203)
- 05000327/LER-1980-203-03, /03L-0:on 801216,during Ice Condenser Insp, Intermediate Deck Door Under AHU-3A Found Frozen Shut. Caused by AHU-3A Drain Line Flange Leaking.Ice Removed from Door,Flange Gasket Replaced & Leakage Stopped + (203)
- 05000327/LER-1980-204-03, /03L-0:on 801216,axial Flux Difference Was Out of Target Band Longer than 1-h.Caused by Rod Stepping to Maintain Power & Blocked Borate Paths Due to Low Heat Trace Setting.Notice to Maintain Temp at 200 F Put on Control + (204)
- 05000327/LER-1980-204, Forwards LER 80-204/03L-0 + (204)
- 05000327/LER-1980-205-03, /03L-0:on 801229 & 810105,two Ice Condenser Intermediate Deck Doors Below AHU-3A Found Frozen Closed. Caused by Overflow from Drip Pan Freezing Around Doors.Ice Removed + (205)
- 05000327/LER-1980-205, Forwards LER 80-205/03L-0 + (205)
- 05000259/LER-2078-205-01, Four Main Steam Isolation Valves Which Exceeded the Leakage Limits of Technical Specification 4.7.A.2.i While Performing Local Leak Rate Testing During Refueling + (205)
- 05000327/LER-1980-206, Forwards LER 80-206/03L-0 + (206)
- 05000327/LER-1980-206-03, /03L-0:on 801225,refueling Water Storage Tank Level Indicator 1-LI-63-50 Found Failing High.Caused by Frozen Instrument Lines for Level Transmitter Inside Cabinet Housing.Lines Thawed Using Heat Gun & Loop Returned to Svc + (206)
- 05000327/LER-1980-207-03, /03L-0:on 801228,remote Shutdown Monitoring Indicators I-LI-68-325C & 326C Showed Erroneous Indication. Caused by Leaking Valve in Common Transmitter Drain Line. Valve Tightened Down + (207)
- 05000327/LER-1980-207, Forwards LER 80-207/03L-0 + (207)
- 05000327/LER-1980-208-03, /03L-0:on 800723,no post-maint Stroke Test Was Performed on Valve 1-FCV-62-72 After Maint Had Been Performed.Cause Not Stated.Emergency Maint Request Issued + (208)
- 05000327/LER-1980-208, Forwards LER 80-208/03L-0 + (208)
- 05000327/LER-1980-209-03, /03L-0:on 800922,no post-maint Testing Performed After Maint on RHR Heat Exchanger Discharge Isolation Valve. Caused by Personnel Error.List Issued Listing All Valves Which Require pre- or post-maint Testing + (209)
- 05000327/LER-1980-209, Forwards LER 80-209/03L-0 + (209)