- ML17328A885 +
- ML102160389 +
- 05000260/LER-1997-002-04, :on 970626,discovered That Four Surveillance Instructions (Sis) Did Not Fully Test All Relay Logic Combinations.Caused by Personnel Error.Verified Relay Contacts Operable & Revised Applicable SIs +
- ML19345C811 +
- ML20041G375 +
- ML040550381 +
- ML20076F369 +
- ML20117E085 +
- ML20115C743 +
- ML20134J904 +
- ML20128B542 +
- ML20066D322 +
- IA-87-216, Submits Daily Highlight.On 870311,while Unit 1 Cooled Down from Hot Functional Test,Severe Water Hammer Event Occurred in RHR Sys Hx.Caused by Operator Apparently Missing Step in Procedure.News Release & Related Info Encl +
- ML20215M470 +
- 05000346/LER-2022-002, Strong Winds Result in Ultimate Heat Sink Low Water Level +
- 05000334/LER-1999-007, :on 990413,manually Initiated Reactor Trip Signal During pre-planned Shutdown of Unit While in Mode 3. Caused by Failure of Cabinet Air Conditioner.Replaced Failed Cabinet Air Conditioner.With +
- 05000498/LER-1988-020, :on 880215,review of Inservice Test on Essential Cooling Water Screen Wash Booster Pump 1A Revealed That Pump Test Data Outside Acceptable Range.Caused by Personnel Error.Special Training Initiated +
- 05000269/LER-1985-006-03, :on 850411,plant Tripped During Divergent Secondary Pressure Swing.Caused by Turbine Header Pressure Control Instabilities.Recirculation Valves Isolated Until Mods Can Be Made +
- 05000454/LER-1985-034, :on 850318,during MSIV Operability Test, Operator Accidentally Actuated Manual Safety Injection Handswitch Instead of Manual Main Steam Isolation Handswitch.Operators Reminded to Read Labels +
- 05000254/LER-1996-007-02, :on 960510,secondary Containment Damaged.Caused by Tornado.Initiated Shutdown,Ac Power Restored to Prompt Notification Sys & Station Blackout Bldg Cables Spliced Per Er 9603099 +
- 05000414/LER-1992-004, :on 920302,TS Surveillance Requirement 3.4.6.2 Missed.Mode 1 Surveillance,Items 10 & 11 Re Unidentified Leakage in Containment Not Performed.Caused by Personnel Error.Tests Performed & Personnel Counselled +
- 05000266/LER-1993-009, :on 931202,EDG G02 Declared Inoperable Due to Relay Malfunction in One of Redundant Starting Circuits. Testing & Insp of STLO-2 Relay Ongoing to Improve Understanding of Root Cause of Failure +
- ML20058L585 +
- 05000341/LER-1989-030, :on 891026,Channel C Level 1 & 2 Replacement Transmitter Found to Be Installed Incorrectly & Condition Recognized on 891210,when Level 2 Trip Unit Was Reading Upscale.Caused by Personnel Error +
- 1CAN128909, Monthly Operating Rept for Nov 1989 for Arkansas Nuclear One,Unit 1 +
- 05000281/LER-1991-011-03, :on 911217,automatic Reactor Trip Occurred as Result of Turbine Trip Due to High SG Level.Caused by Failure of B Main FW Regulating Valve to Maintain Demand Position.Valve Inspected,Replaced & Tested +
- 05000272/LER-1991-027, :on 910815,two Partial Mode Op I 1A Safeguard Equipment Control Cabinet Signal Actuations Occurred.Caused by Equipment Failure.Chassis Replaced & Failed Cards Sent to Mfg +
- 05000354/LER-2005-004, A Control Room Emergency Filtration (CREF) Train Inoperable with B CREF Out of Service +
- 05000219/LER-1986-034, :on 861229,reactor Manually Scrammed Due to Inability to Maintain Condenser Vacuum.Caused by Equipment Failure & Cooldown in Excess of Tech Spec Limit.Failed Relief Valve & Expansion Joint Replaced +