- ENS 45173 +
- ML20012C467 +
- ML20005G555 +
- AEP-NRC-2012-35, Submittal of Spill Notification for Groundwater Permit No. GW1810102, NPDES Permit No. Gw 0005827 +
- ML19345C811 +
- 05000395/LER-1991-006, Forwards LER 91-006 Re Inadvertent ESF Actuation of DG in Response to Violation Noted in Insp Rept 50-395/91-17. Corrective Actions:Operations Staff Briefed on Necessity of Attention to Detail +
- ML20081M865 +
- ML20080T751 +
- ML20136G465 +
- ML20136F702 +
- PNO-V-85-075, on 851102,plant Attained Criticality & Commenced Power Operation on 851103.Plant Has Been Shut Down Since 851002 Due to Loss of Main Feedwater Event +
- ML20128N261 +
- ML20065J013 +
- 1CAN068406, Monthly Operating Rept for May 1984 +
- 05000498/LER-1988-026, :on 880330,reactor Trip & Safety Injection Sequence Initiated Due to Partial Offsite Power Loss.Caused by Personnel Error & Design Inadequacy.Event Incorporated in Training Session & Protection Sys Evaluated +
- 05000382/LER-1988-016, :on 880614,reactor Trip Due to Turbine Control Sys Failure & Procedural Inadequacy.Caused by Equipment Malfunction.Procedures Being Revised to Include Precautions for Overspeed Protection Control Testing +
- 05000334/LER-1997-002-01, :on 970219,declared EDGs Inoperable Due to Inaccuracies of Watt Meter Instrument Loop.Restored EDG Operability Via Performance of Revised Operating Surveillance Tests +
- 05000269/LER-1985-006-03, :on 850411,plant Tripped During Divergent Secondary Pressure Swing.Caused by Turbine Header Pressure Control Instabilities.Recirculation Valves Isolated Until Mods Can Be Made +
- 05000269/LER-1985-005-03, :on 850411,reactor Trip Occurred Upon Closure of Low Pressure Turbine Intercept Valves & Main Turbine Control Valves.Caused by Faulty Edge Connector on Circuit Board of Electrohydraulic Control Sys +
- 05000269/LER-1985-005-01, :on 850411,reactor Tripped from 100% Full Power Upon Closure of Low Pressure Turbine Intercept Valves & Main Turbine Control Valves.Caused by High Turbine Header Pressure & Reduced Heat Transfer +
- 05000293/LER-1996-005, :on 960419,automatic Scram Occurred Due to Turbine Vibration During Planned Power Reduction.Turbine Vibration Trip Setting That Initiates Trip of Turbine Due to High Vibration Changed +
- 05000382/LER-1991-022, :on 911117,reactor Trip Occurred on Loss of Power to Control Element Drive Mechanism Motor Generator Sets Due to Sias.Caused by Test Circuit Malfunction.Loose Connections Tightened +
- 05000413/LER-1989-027, :on 891120,Tech Spec Required Unit Shutdown Due to Inoperable Chemical & Vol Control Centrifugal Pump.W/ +
- IR 05000321/1993300 +
- 05000373/LER-1990-008-04, :on 900525,Tech Spec Hourly Fire Watch Missed Due to Miscommunications Between Security Personnel & Radiation Protection Personnel.Fire Watch re-established & Memo Issued +
- 05000353/LER-1990-002, :on 900105,containment H2/O2 Analyzer Declared Inoperable During Containment Inerting.Caused by Reversed Tubing Connections in Installation of Analyzer Due to Mislabeling.Analyzer Restored +
- ML20036B253 +
- ML20085G342 +