Monthly Operating Repts for Feb 1997 for Beaver Valley Power Station,Unit 1 & 2
ML20136G465
Person / Time
Site: Beaver Valley
Issue date: 02/28/1997
From: David Jones, Legrand R
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9703180048
Download: ML20136G465 (9)


Text

gy

'yp Telephone (412) 393-8000

    1. t3 "."PA 15077-0004 Shippingport March 6,1997 Beaver Valley Power Station Unit 1 - Docket No 50-334, License No. DPR-66 Unit 2 - Docket No. 50-412, License No. NPF-73 Monthly Operating Report U. S. Nuclear Regulatory Commission Document Control Desk Washington,DC 20555 Gentlemen:

In accordance with Appendix A, Technical Specifications, the Monthly Operating Report is submitted for Unit I and Unit 2 for the month ofFebruary,1997.

Respectfully, h-m R. L. LeGrand Division Vice President, Nuclear Operations /

Plant Manager DTJ/ sip Enclosures I

cc:

NRC Regional Office King of Prussia, PA 9703180048 970228 PDR ADOCK 05000334 R

PDR The Nuclear Professionals 180014 lingpapppppgy

NARRATIVE

SUMMARY

OF MONTHLY OPERATING EXPERIENCE i

UNIT 1 i

FEBRUARY 1997 i

i February 1 The Unit operated at a nominal value of 100% output for the entire report period.

through However, at 2240 hours0.0259 days <br />0.622 hours <br />0.0037 weeks <br />8.5232e-4 months <br /> on 02/19/97, the Unit initiated a plant shutdown per February 28 Technical Specifications due to both Emergency Diesel Generators being considered inoperable. At 2246 hours0.026 days <br />0.624 hours <br />0.00371 weeks <br />8.54603e-4 months <br /> with Turbine load reduced by approximately 10 MWe, 4

i one of two Emergency Diesel Generators was returned to service and the required Technical Specification shutdown was aborted. Turbine load was returned to full '

output and the second Emergency Diesel Generator was subsequently returned to i

service at 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> on 02/20/97.

1 In addition to the above, the following events which also occurred during the report period are being reported as required by Technical Specifications.

- February 1 The Automatic Rod Position Deviation Monitor, although still functional, was not through considered openble per Technical Specifications.

The limiting condition for February 28 operation as specified in the Technical Specifications was met because the deviations between the ind:cated rod positions were verified to be within their 12 step limits by obtaining analog / digital rod positions at least once every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

I n

___. - - = _ -. -. -

AVERAGE DAILY UNIT POWER LEVEL I

i DOCKET NO. 50-334 UNIT BVPS Unit 1 DATE March 3,1997 COMPLETED BY David T. Jones i

4 TELEPHONE (412)393-4962 l

4 I

MONTH February 1997 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 828 17 828 2

828 18 821 3

827 19 822 4

828 20 822 5

829 21 811 6

829 22 823 7

829 23 828 8

831 24 828 9

831 25 828 10 830 26 827 11 829 27 818 12 830 28 829 13 828 29 14 827 30 15 830 31 16 829 INSTRUCTIONS On this form, list the average daily unit power level MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

.... ~

l J

i i

1 OPERATING DATA REPORT DOCKET NO.*

50-334 REPORT DATE:

03/05/97 COMPLETED BY: DAVID T. JONES TELEPHONE:

(412) 393 4962 1

l OPERATING STATUS

].

1. UNIT NAME: BEAVER VALLEY POWER STATION, UNIT 1
  • Notes
2. REPORTING PERIOD: FEBRUARY 1997 4
3. LICENSED THERMAL POWER (MWt):

2652 1

f 4.

NAMEPLATE RATING (Gross MWe) :

923

5. DESIGN ELECTRICAL RATING (Net MWe)-

835

6. MAX. DEPENDABLE CAPACITY (Gross MWe) :

860 7

MAX. DEPENDABLE CAPACITY (Net MWe):

810 8.

IF CRANGES OCCUR IN CAPACITY RATINGS SINCE LAST REPORT, GIVE REASONS:

9.

POWER LEVEL TO WHICH RESTRICTED, IF ANY (Net MWe).

None i

10. REASONS FOR RESTRICTIONS, IF ANY:

N/A 1

i 4

i THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD:

672.0 1416.0 182616.0

12. NO. OF HRS. REACTOR WAS CRITICAL:

672.0 1416.0 122063.9

13. REACTOR RESERVE SHUTDOWN HOURS:

0.0 0.0 4482.8

14. HOURS GENERATOF.WAS ON LINE:

672.0 1416.0 119902.6

15. UNIT RESERVE SHUTDOWN HOURS:

0.0 0.0 0.0

16. GROSS THERMAL ENERGY GEN. (MWH) :

1744174.0 3701812.0 290975554.5 1

17. GROSS ELECT. ENERGY GEN. (MWH)?

588070.0 1236490.0 94104082.0' I

18. NET ELECTRICAL ENERGY GEN. (MWH) :

555620.0 1169400.0 88030969.0

19. UNIT SERVICE FACTOR: (PERCENT) 100.0 100.0 67.4
20. UNIT AVAILABILITY FACTOR:(PERCENT) 100.0 100.0 67.4
21. UNIT CAPACITY FACTOR (MDC): PCT 102.1 102.0 61.8
22. UNIT CAPACITY FACTOR (DER): PCT 99.0 98.9 60.0
23. UNIT FORCED OUTAGE RATE: (PERCENT) 0.0 0.0 14.8
24. SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE,DATE, AND DURATION OF EACH) :
25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
26. UNITS.IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION) :

FORECAST ACHIEVED INITIAL CRITICALITY N/A N/A INITIAL ELECTRICITY N/A N/A COMMERCIAL OPERATION N/A N/A

UNIT SHUTDOWNS AND POWER REDUCTIONS (220%)

Docket No. 50-334 Unit Name BVPS Unit #1 Date March 3,1997 Completed By David T. Jones REPORT MONTH Febmary 1997 Telephone (412)393-4 % 2 No.

Date Typel Duration Reason 2 Method of Licensee System Component Cause & Correctist Action to Prevent (Hours)

Shutting Event Report #

Code 4 Code 5 Recurrence Down Reactor 3 None I

2 3

4 F-Forced Reason:

Method Exhibit F-Inmuchoes for Preparahan of Data Entry S-Sdieduled A-Equipment Failure (Explain)

I-Manual Sheets for Lacensee Event Report (IIR) File B-Mastenance or Test 2-Manual Scram (NUREG0161)

C-Refueling 3-Automahc Saam D-Regulatory Restrichon 4-Carfd from Previous Month E-Operator Training & Ijeense Exam 5-Reduction 5

F-Administrative 9-Other Exhitst II-Same Sourse G4hu: rational Error (Explain) 1I4hher(Explain)

L

_ _ 7_ _

.t NARRATIVE

SUMMARY

OF 4

MONTHLY OPERATING EXPERIENCE UNIT 2 FEBRUARY 1997 i

February 1 The Unit operated at a nominal value of 100% output.

through February 17 February 18 At 2032 hours0.0235 days <br />0.564 hours <br />0.00336 weeks <br />7.73176e-4 months <br />, approximately 10 MWe of output was lost due to a loss of efficiency when the IIigh Level Dump Valve for the "B" Reheater Drain Receiver Tank failed open due to failure ofit's air supply line. As a result, a slight power reduction was made at 2110 hours0.0244 days <br />0.586 hours <br />0.00349 weeks <br />8.02855e-4 months <br /> to match Tavg with Tref.

February 19 The valve was isolated for repairs and the Unit was subsequently returned to full power at 0535 hours0.00619 days <br />0.149 hours <br />8.845899e-4 weeks <br />2.035675e-4 months <br />.

February 20 The Unit operated at a nominal value of 100% output for the remainder of the report through period.

February 28 i

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-412 UNIT BVPS Unit 2 DATE March 3,1997 COMPLETED BY David T. Jones TELEPHONE (412) 393-4962 MONTH Februaiv 1997 I

i DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 841 17 844 2

842 18 838 3

841 19 836 4

839 20 837 l

5 840 21 829 6

845 22 841 7

845 23 843 8

844 24 843 j

9 845 25 842 10 842 26 841 11 844 27 836 12 845 28 843 13 845 29 14 842 30 15 845 31 16 844 INSTRUCTIONS On this form, list the average daily unit power level MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

e OPERATING DATA REPORT DOCKET NO :

50-412 REPORT DATE:

03/05/97 COMPLETED BY: DAVID T. JONES TELEPHONE:

(412) 393-4962 OPERATING STATUS

'1. UNIT NAME: BEAVER VALLEY POWER STATION, UNIT 2

  • Notes 2.

REPORTING PERIOD: FEBRUARY 1997 3.

LICENSED THERMAL POWER (MWt) :

2652 4.

NAMEPLATE RATING (Gross MWe) :

923

5. DESIGN' ELECTRICAL RATING (Net MWe):

836-6.

MAX. DEPENDABLE CAPACITY (Gross MWe) -

870 7,

MAX. DEPENDABLE CAPACITY (Net MWe):

820 8.

IF CHANGES OCCUR IN CAPACITY RATINGS SINCE LAST REPORT, GIVE REASONS:

l

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (Net MWe) :

None

10. REASONS FOR RESTRICTIONS, IF ANY:

N/A THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD:

672.0 1416.0 81399.0

12. NO. OF HRS. REACTOR WAS CRITICAL:

672.0 1210.7 68931.7

13. REACTOR RESERVE SHUTDOWN HOURS:

0.0 0.0 0.0

14. HOURS GENERATOR WAS ON LINE:

672.0 1192.8 68457.5

15. UNIT RESERVE SHUTDOWN HOURS:

0.0 0.0 0.0

16. GROSS THERMAL ENERGY GEN. (MWH):

1773166.0 3005961.0 170217804.0

17. GROSS ELECT.-ENERGY GEN. (MWH):

594765.0 1000126.0 55496549.0

18. NET ELECTRICAL ENERGY GEN. (MWH):

565474.0 942767.0 52431363.0

19. UNIT SERVICE FACTOR: (PERCENT) 100.0 84.2 84,1
20. UNIT AVAILABILITY FACTOR:(PERCENT) 100.0 84.2 84.1
21. UNIT CAPACITY FACTOR (MDC) : PCT 102.6 81.2 78.2
22. UNIT CAPACITY FACTOR (DER) : PCT 100.7 79.6 77.0
23. UNIT FORCED OUTAGE RATE: (PERCENT) 0.0 15.8 4.6
24. SHUTDOWNS SCHEDULED OVER NEXT SIX MONTHS (TYPE,DATE,AND DURATION OF EACH):
25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION) :

FORECAST ACHIEVED INITIAL CRITICALITY N/A N/A INITIAL ELECTRICITY N/A N/A COMMERCIAL OPERATION N/A N/A j

I

)

UNIT SHUTDOWNS AND POWER REDUCTIONS (220%)

Docket No. 50-412 Unit Name BVPS Unit #2 Date March 3, IP7 Completed By David T. Jones REPORT MONTil February 1997 Telephone (412)393-4 % 2 No.

Date Typel Duration Reason 2 Method of Licensee System Component Cause & Corrective Action to Prevent (flours)

Shutting Event Report #

Code 4 Codes Recurrence Down Reactor 3 None I

2 3

4 F-Fonxd Reason:

Method:

Exinbit F-Instructions for P garshon of Data Entry S-Scheduled A-Equipment Failure (Explain) 1-Manual Sheets for Ixensee Evers Report (LER) File B-Maintenance er Test 2-Manual Scram (NUREGGI61).

C-Refuehng 3-Automatic Scrarn D-Regulatory Restriction 4-Corm'd frorn Prevunas Month E@ator Traming & License Exam 5-Rethetson 5

F-Achnenistrative 9-Other Eximbit H-Same Source G@ational Error (Explain)

Il4)ihar(Eglain)

-