Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ENS 46241 +
- 05000272/LER-1992-019, :on 920805,main Steam Line Isolation Occurred Due to Design,Manufacturing,Construction/Installation Inadequacy.Design Mod in Progress to Correct Main Streamline Flow Sensing Line +
- ML19340F000 +
- ML20004F381 +
- L-03-043, February 2003 Monthly Operating Report for Beaver Valley Power Station, Units 1 & 2 +
- ML20070E727 +
- ML20199D384 +
- ML20212E724 +
- ML20246C909 +
- ML20236B094 +
- ML20214W031 +
- ML20216J789 +
- 05000293/LER-1999-003, :on 990516,discovered That LLRT Results Exceeded Allowable TS Leakage Rates.Cause Indeterminate. Affected Valves Were Disassembled & Inspected & Damaged or Worn Parts Were Reworked or Replaced.With +
- 05000334/LER-1985-018, :on 851004,w/unit at 40% Power,First Out Annunciators & Vital Bus III Inverter Trouble Alarm Annunciated.Caused by Misfiring Silicon Control Rectifier. Plant Stabilized Per Emergency Procedures +
- 05000413/LER-1996-014, :on 961230,solid State Protection Sys Train B Relay K616 Properly Actuated,Failed to Latch in Tripped Position During Periodic Main Steam Line Isolation Testing. Caused by Equipment failure.K616 Replaced +
- 05000293/LER-1992-004, :on 920326 & 27,three Automatic PCIS Group 1 Isolations Occurred During Plant Shutdown Due to False High Rv Water Level Signals.Insulation Removed from B Head Equalizing Line +
- 05000352/LER-1991-027-01, :on 911112,inadvertent Actuation of Primary Containment & Reactor Vessel Isolation Control Sys Resulted in Closure of Gas Analyzer Sample Lines to Drywell.Cause Undetermined.Defective Relay Replaced +
- 05000293/LER-1993-012, :on 930529,unplanned PCIS Group I Isolation Signal Occurred While Opening MSIV During Startup,Resulting in Automatic Closing of Related Valves.Caused by Licensed Operator Error.Group 1 Isolation Reset +
- ML20035E693 +
- ML20032D877 +
- 05000286/LER-2018-002, Manual Reactor Shutdown Due to Weld Leak in Safety Injection System Tank +
- 05000410/LER-1988-024, :on 880605,ESF Actuation Occurred Due to Resetting of Failed Radiation Monitor Microcomputer.Caused by Lack of Personnel Training.Defective Cards & Modules in RE14B Microcomputer & DRMS Panel Replaced +
- 05000259/LER-2013-008, (Bfn), Unit 1, Fire Damage to Cables in Fire Areas Could Cause Residual Heat Removal Pumps to Spuriously Start +
- 05000346/LER-1998-002-01, Regarding Plant Trip Due to High Pressurizer Level as a Result of Loss of Letdown Capability +
- 05000293/LER-1999-003-01, Re Local Leak Rate Test Results Exceeding Allowable Technical Specification Leakage Rates +
- 05000341/LER-1998-007, :on 980908,inadvertent Deenergization of Safety Buses During Performance of Surveillance Testing Resulted in ESF Actuations.Caused by Faulty Static Underfrequency Relay. Relay Was Removed & Benched Tested +
- 05000354/LER-1997-004, :on 970207,B Div Primary Containment Isolation Sys Isolation Occurred.Caused by Personnel Error During Troubleshooting.Failed Optical Isolator Replaced & Channel Calibr Satisfactorily Completed on 970208 +
- 05000346/LER-1990-010, :on 900518,inadvertent Safety Features Actuation W/Injection of 1,000 Gallons Borated Water Occurred W/Plant in Mode 5.Caused by Loss of 120 Volt Ac Bus Y3.Personnel Retrained +