Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ENS 46473 +
- 05000325/LER-2005-006 +
- ML061030266 +
- ML15071A343 +
- BSEP 11-0004, Voluntary Groundwater Protection Plan Report +
- ML15107A154 +
- ML20084E320 +
- ML20078G038 +
- IR 05000255/1985027 +
- ML20133J496 +
- IR 05000255/1985023 +
- 2CAN018703, Monthly Operating Rept for Dec 1986 +
- L-98-178, Monthly Operating Repts for Aug 1998 for Bvps,Units 1 & 2. with +
- 05000346/LER-1998-006, :on 980624,loss of Offsite Power Was Noted. Caused by Tornado Damage to Switchyard.Tested & Repaired Affected Electrical & Mechanical Equipment Necessary to Restore Two Offsite Power Sources +
- 05000334/LER-1989-002-01, :on 890213,reactor Trip Occurred Due to Feedwater Regulating Valve (MFRV) Malfunction.Caused by Failure of electro-pneumatic transducer.Electro-pneumatic Transducers for Valves Replaced +
- 05000339/LER-1986-006-02, :on 860416,determined That Specific Gravities of Various Battery Cells on Dc Busses Below Tech Spec Min. Exide Corp Determined Batteries Meet Vendor Requirements. Addl Investigation in Progress +
- 05000412/LER-1999-001-01, :on 990227,failure to Comply with TSs Due to Not Meeting Acceptance Criteria for Source Range Monitor During Surveillance Testing,Was Discovered.Caused by Lack of Attention.Procedure 20ST-2.3 re-performed.With +
- 05000334/LER-1997-033, :on 971008,identified Potential for Nis Supply Voltages to Be Outside of Design Requirements.Caused by Inadequate Design Change During Original Construction of Plant.Developed & Implemented Design Change +
- 05000267/LER-1985-024, :on 851107,25 Incorrect Rod Sequence Rod Withdrawal Prohibits Received During Reactor Shutdown Operations.Caused by Incorrect Positioning of Rod Select Switch HS-1221.Switch Placed in Off Position +
- 05000244/LER-1985-013, :on 850531,one Emergency Diesel Generator Started Per Adverse Weather Emergency Plan Due to Notification of Tornado Warning.Generator Removed from Svc When Tornado Warning Rescinded +
- 05000413/LER-1985-023, :on 850329,reactor Power Exceeded 75% W/Only Two of Three Test Runs for Reactor Coolant Sys Performed. Caused by Software Problem.Thermal Output Calculations Program Modified,Reassembled & Reimplemented +
- 05000270/LER-1984-001-06, :on 841127,reactor Bldg Spray Trains Inadvertently Removed from Svc.Caused by Personnel Error. Situation Corrected by Reclosing Breaker for Train Not Being Tested +
- 05000414/LER-1993-002-04, :on 930331,unexpected Esfa Occurred When Steam Dump Sys Opened.Caused by Sys Failure Due to Degraded Subcomponent.Loop Power Supply Card & Pressure Transmitter Replaced +
- 05000334/LER-1981-062-03, /03L-0:on 810619,auxiliary Flow Path to Steam Generator 1A Was Isolated.Caused by Maint on Leaking Feed Flow Transmitter Instrument Line Penetration Into Auxiliary Feed Flow Header A.Piping Refabricated +
- 05000374/LER-2015-003, Regarding Reactor Recirculation Loop Discharge Isolation Valve Vent Line Leak Due to Weld Defect +
- 05000259/LER-2011-005, Regarding Reactor Water Level Scram Due to Distracted Operations Crew +
- ML17193A725 +
- 05000354/LER-2004-010, Manual Reactor Scram Due to Moisture Separator Dump Line Failure +
- 05000346/LER-1998-002-01, Regarding Plant Trip Due to High Pressurizer Level as a Result of Loss of Letdown Capability +
- 05000339/LER-1986-006, :on 860416,discovered Specific Gravities of Battery Cells on 3 of 4 Dc Busses Below Min.Caused by Failure to Correct Specific Gravities to Full Electrolyte Level.Administrative Procedure Revised +