Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ENS 40476 +
- ML17328A321 +
- ML093280761 +
- BSEP 16-0020, Request for Notice of Enforcement Discretion (Noed), Limiting Condition for Operation (LCO) 3.0.3, Per Technical Specification 3.8.1, AC Sources - Operating +
- ML20039G481 +
- ML20039G181 +
- ML093640783 +
- JAFP-03-0068, March 2003 Monthly Operating Report for James A. FitzPatrick, Revision 1 +
- JAFP-03-0050, March 2003 Monthly Operating Report for James A.Fitzpatrick Nuclear Power Plant +
- ML20083L369 +
- ML20083B560 +
- ML20078F765 +
- ML20100R284 +
- ML20107D325 +
- ML20101B206 +
- ML20137B616 +
- IR 05000346/1987027 +
- IR 05000352/1985037 +
- ML20151D460 +
- ML20199D294 +
- ML20205C196 +
- ML20245F266 +
- ML20235J596 +
- ML20214V088 +
- ML102360282 +
- IR 05000254/1987002 +
- 05000267/LER-1989-011, :on 890623,discovered That Reheat Steam Attemperation Flow Not Accounted for in Secondary Heat Balance Calculation of Reactor Power.Caused by Inadequate Procedures.Procedure Changes Implemented +
- 05000331/LER-1989-006, :on 890224,isolation of RCIC & on 890302, Isolation of HPCI Occurred.Caused by Problems in Electrical Path from Thermocouples Monitoring Area Temp.Retermination of Broken Thermocouple Wire Before Break +
- 05000219/LER-1989-011, :on 890422,equipment Operator Failed to Properly Align Seal Water Makeup Supply.Caused by Oversight by Operator.Procedures in Hand Requirement Shall Apply to Evolution +
- 05000285/LER-1987-038, :on 871130,leak Rate in Excess of 18,000 Sccm Tech Spec Limit Found.Caused by Position of Valve Being Slightly Past Fully Closed Position.Adjustment of Mechanical Stops for Actuator Corrected +
- 05000368/LER-1987-009, :on 871114,subcritical Reactor Trip Occurred While Performing Reactor Shutdown.Caused by Procedural Deficiency.Proper Actuation of Reactor Protection Sys Verified.Procedure Will Be Revised +
- 05000313/LER-1987-006-01, :on 871103,discovered Penetration Room Ventilation Sys Surveillance Not Performed Prior to Establishing Reactor Bldg Integrity.Caused by Inadequate Procedural Guidance.Procedure to Be Revised +
- 05000265/LER-1987-001, :on 870103,1/2 Diesel Generator Failed to auto- Start During Core Spray Logic Testing.Caused by Design Error in Electrical Wiring Drawing.Ground Isolated & Fuse Replaced.Wiring Corrected +
- 05000265/LER-1987-001-03, :on 870103,during Core Spray Logic testing,1/2 Diesel Generator Did Not auto-start During Simulated Initiation Signals.Caused by Blown Negative Fuse in auto- Start Circuit.Fuse Replaced +
- 05000341/LER-1986-045, :on 861117,during Sys Restoration,Incorrect Valving Sequence Caused Damage to Test Return Line for Condensate Storage & Return Tanks.On 861201,water Collected in Cable Vaults Released to Outflow Canal +
- 05000331/LER-1987-003, :on 870223,RWCU Sys Isolated on Signal from Room B Differential Temp Switch Located in RWCU Pump Room. Caused by Failure of Redundant Instrumentation. Instrumentation Replaced +
- 05000269/LER-1998-017-01, :on 981128,missed Surveillance Was Noted.Caused by Inadequate Work Planning.Operations Mgt Expectations for Performance of Qpt SR Were Communicated to Appropriate Operations Personnel +
- 05000331/LER-1986-010, :on 860408,HPCI Sys Failed to Meet Discharge Pressure & Flow Requirements.Caused by Woodward EG-M Control Box Needing Recalibr.Box Recalibr & Hydraulic Control Tappet Valve Body Repaired +
- 05000265/LER-1987-002-11, :on 870122,RCIC Turbine Outboard Bearing Flooded W/Oil & Turbine Inboard Oil Level Was Too Low.Caused by Mod Design Deficiency.Defective Bearing Replaced & Maint Procedure Will Be Developed +
- 05000334/LER-1997-018, :on 970705,potential for Spurious Seismically Induced FPS Sys Activation Affecting EDG Was Noted.Caused by Deficiency in Original Design.Established Fire Watch +
- 05000265/LER-1988-002-01, :on 870122,RCIC Isolated & Declared Inoperable Due to Oil Flooding Outboard Bearing.Caused by Mod Design Deficiency Installed During Refuel Outage.Bearing Replaced & Oil Orifice Cleaned & Reinstalled +
- 05000261/LER-1985-022-01, :on 850928,Exxon Nuclear Corp Informed Util of Error in Large Break LOCA Analysis Which Resulted in Peak Clad Temp Being Underpredicted.Reactor Power & High Flux Trip Setpoint Increased within New Limits +
- 05000461/LER-1996-020, :on 961223,failure of CR Drive Hydraulic Control Unit Air Line Occurred Due to Overtightening Fitting During Maintenance to Correct Air Leak.Broken Air Line Was Replaced in Accordance with Mwr D61669 +
- 05000389/LER-1985-009-02, :on 850910,high Vibrations Occurred on Reactor Coolant Pump 2A2,causing Manual Trip.Caused by Pump Vibration Permitting Oil Slinger Ring to Break Free & Damaged Oil Seal in Oil Reservoir +
- 05000311/LER-1985-005, :on 850417,reactor/turbine Trip Occurred During Startup Operations.Caused by Corrosion Products Collected in Reheat Steam Drain Line Piping Following Extended Shutdown. Procedural Review to Be Performed Re Blowdown +
- 05000331/LER-1985-001, :on 850123,reactor Water Cleanup Sys Isolated Twice as Result of Momentary Spurious Signals from Reactor Water Cleanup Leak Detection Instrumentation.Cause Not Stated.Sys Will Be Tested in Refuel Outage +
- 05000413/LER-1992-001, :on 920107,secured Upper Containment Unit Fan 1C to Allow for One Containment Air Pressure Release Instead of Normal Two Per Shift.Caused by Inappropriate Action. Changes to Procedures Proposed +
- 05000395/LER-1984-016, :on 840301,following Maint,Diesel Generator a Emergency Safety Feature Load Sequencer Started to Sequence.Caused by Faulty one-shot Multivibrator Electronic Card.Sequencer Repaired +
- 05000293/LER-1991-007, :on 910429,TS Required Shutdown Completed Due to Drywell Floor Sump Leakage Rate & Subsequent Scram Signal While Shutdown.Seal Cartridges Replaced & Responsible Operator Counseled +
- 05000482/LER-1994-006, :on 940615,Limitorque Actuators on MOVs in ESW Lines to & from Component Cooling Water HXs Changed Out in Both Safety Trains.Caused by Inadequate Job Scoping. Performance Improvement Request Initiated +