- ENS 40433 +
- 05000390/LER-2001-003 +
- 05000354/LER-2001-001 +
- ML18066A876 +
- ML18058B875 +
- ENS 43688 +
- ML20073F254 +
- PLA-7859, Annual Radiological Environmental Operating Report - PLA-7859 +
- ML20082M127 +
- ML20077L493 +
- ML20154H569 +
- ML20065C584 +
- ML20215M332 +
- ST-HL-AE-3128, Special Rept:On 890523,24 & 0608,diesel Generator 13 Tripped During Testing Procedures.First Failure Caused by Increased Resistance Across Contacts of Unit Parallel Mode & Second & Third Failures by Inadequate Air Flow.Contacts Cleaned +
- 05000155/LER-1989-005-01, :on 890222,resident Inspector Observed Some Degradation on Rubber Seal of Containment Vent Valve.Shift Supervisor Conducted 10CFR50,App J Type B Leak Rate Test & Found Unacceptable Leakage.Caused by Aging +
- 05000260/LER-1989-018, :on 890606,diesel Generator a Declared Inoperable Resulting in Inoperability of RHR 2A Pump & Failure to Comply W/Tech Specs.Caused by Failure to Detect Damage from Corrosion Debris +
- 05000334/LER-1997-024, :on 970805,TS 3.0.3 Was Entered as Result of Failure of RWST Level Transmitter.Caused by Crack in Ferrite Block for Level Transmitter LT-QS-100B.Replaced Transmitter W/Foxboro Model 827DF-IS1SHSA1 +
- 05000382/LER-1988-025, :on 881010,several Discrepancies Associated W/ Fire Rated Assemblies Discovered That Were Not Included in Surveillance Procedure ME-3-009, Fire Walls,Floors, Ceilings. Caused by Procedural Inadequacy +
- 05000155/LER-1987-005-01, :on 870222,CRD Changeout Commenced W/Mode Switch in Refuel Position.Caused by Poor Communication Between Maint Crew & Control Room & Missed sign-off in Replacement Procedure.Personnel Counseled +
- 05000293/LER-1988-014, :on 880426,automatic Closing of Outboard Primary Containment Sys Group 6 Isolation Valves Occurred. Caused by Failure of Coil of Outboard Primary Containment Isolation Control Sys.Coil & Fuse Replaced +
- 05000341/LER-1988-007, :on 880214,deenergized Radiation Monitor Caused Control Ctr HVAC to Shift to Recirculation Mode.Caused by Improper Review of Sys Functions Prior to Performing Work. Personnel Involved Counseled on Event +
- 05000334/LER-1996-012, :on 961006,entry Into TS 3.0.3 Occurred Due to Isolation of CR Breathing Air Pressurization Sys.Verified Crebaps Actuation Was Inadvertent & Reset Signal at Approximately 1503 Hours on 961006 +
- 05000352/LER-1994-010, :on 940626,operator Pulled an Incorrect Fuse Which Caused Indicating Lights to Extinguish.Caused by Less than Adequate Attention to Detail.Both RO & Co Were Disciplined to Meet Management Expectation +
- ML19337A210 +
- 05000296/LER-2009-003, Brown Ferry, Unit 3 Re Reactor Core Isolation Cooling System Inoperable Longer than Allowed by the Technical Specifications +
- 05000251/LER-2005-006, Regarding Manual Reactor Trip Due to Rod Control Urgent Failure Alarm +
- 05000267/LER-1986-011, :on 860201,automatic Loop 2 Shutdown Initiated on High Reheat Header Activity.Caused by Voltage Spike When RIS-93252-11 Manually Tripped Causing RIS-93251-11 to Trip. Station Svc Request Initiated to Test Switch +
- 05000312/LER-1988-005, :on 880315 & 22,steam/water Transients Caused Relief Valves to Lift & Result in Discharge of Water from Letdown Sys to Reactor Bldg Sump.Caused by Pressure Spike Due to Acceleration Slug of Water +