- ML20127M478 + (ML20127M478)
- 05000354/LER-1992-014-02, :on 921023,RWCU & RHR Sys Isolation Occurred as Result of Partial Loss of Power to Nssss Sys Control Logic. Caused by Design Deficiency.Engineering Evaluation Underway to Determine If Addl Mods Required + (ML20127M480)
- ML20127M481 + (ML20127M481)
- ML20127M482 + (ML20127M482)
- AECM-85-0165, Identifies Addl Exceptions to Literal Requirements of 10CFR50,App R for Some Fire Areas as Suppl to 850507 Summary Rept of Findings in Review of Fire Protection.Exceptions Pertain to Fire Barrier Wrapping of Cable Raceways + (ML20127M483)
- ML20127M486 + (ML20127M486)
- 05000254/LER-1992-026-02, :on 921027,discovered That RCIC Flow Transmitter Out of Calibr,Resulting in Pump Flow Below TS Requirements.Caused by Setpoint Drift.Calibr of Flow Transmitter Verified + (ML20127M488)
- ML20127M489 + (ML20127M489)
- ML20127M490 + (ML20127M490)
- ML20127M492 + (ML20127M492)
- 05000293/LER-1985-010, :on 850412,two in-series Secondary Containment Isolation Dampers Would Not Fully Close.Caused by Slippage in Drive Gears & Cracking Due to Aging & Fatigue.Gears Replaced + (ML20127M493)
- ML20127M494 + (ML20127M494)
- ML20127M495 + (ML20127M495)
- ML20127M496 + (ML20127M496)
- ML20127M497 + (ML20127M497)
- ML20127M498 + (ML20127M498)
- ML20127M500 + (ML20127M500)
- ML20127M501 + (ML20127M501)
- ML20127M504 + (ML20127M504)
- ML20127M505 + (ML20127M505)
- ML20127M506 + (ML20127M506)
- B14291, Proposed TS 3/4 6-3.d Increasing Type B & C Surveillance Testing Intervals from 24 Months to 34 Months for Cycle 4 Only + (ML20127M507)
- ML20127M508 + (ML20127M508)
- ML20127M509 + (ML20127M509)
- ML20127M510 + (ML20127M510)
- ML20127M511 + (ML20127M511)
- ML20127M512 + (ML20127M512)
- 05000327/LER-1992-018, :on 921026,reactor Tripped Due to Turbine Trip. Caused by hi-hi Feedwater Level in SG 3 & Failure in automatic-manual Switching Relay.Unit Stabilized in Hot Standby & Relays Replaced + (ML20127M513)
- ML20127M515 + (ML20127M515)
- U-602066, Responds to NRC 921014 Request That Util Reconsider Submittal Schedule & Complete IPE of External Events,Per Suppl 4 to GL 88-20 Earlier than Requested Date of June 1994.Schedule Should Not Be Accelerated + (ML20127M516)
- ML20127M517 + (ML20127M517)
- ML20127M518 + (ML20127M518)
- ML20127M520 + (ML20127M520)
- ML20127M521 + (ML20127M521)
- ML20127M522 + (ML20127M522)
- ML20127M523 + (ML20127M523)
- ML20127M524 + (ML20127M524)
- ML20127M525 + (ML20127M525)
- ML20127M526 + (ML20127M526)
- ML20127M529 + (ML20127M529)
- ML20127M530 + (ML20127M530)
- ML20127M532 + (ML20127M532)
- ML20127M533 + (ML20127M533)
- ML20127M536 + (ML20127M536)
- ML20127M537 + (ML20127M537)
- ML20127M539 + (ML20127M539)
- ML20127M540 + (ML20127M540)
- ML20127M541 + (ML20127M541)
- ML20127M543 + (ML20127M543)
- ML20127M544 + (ML20127M544)
- ML20127M545 + (ML20127M545)