- ML20112D633 + (ML20112D633)
- ML20112D636 + (ML20112D636)
- 05000366/LER-1984-035, :on 841213,RCIC Declared Inoperable When Inboard Steam Supply Isolation Valve 2E51-F007 auto-isolated.Caused by Failed Card (Electronic Circuit Board).Failed Card Replaced + (ML20112D639)
- ML20112D640 + (ML20112D640)
- ML20112D641 + (ML20112D641)
- ML20112D646 + (ML20112D646)
- ML20112D652 + (ML20112D652)
- ML20112D661 + (ML20112D661)
- ML20112D662 + (ML20112D662)
- ML20112D668 + (ML20112D668)
- JAFP-96-0226, Forwards Response to Violations Noted in Insp Rept 50-333/96-02.Corrective Actions:Programmatic Assessment Performed on Foreign Matl Exclusion Program + (ML20112D673)
- ML20112D679 + (ML20112D679)
- 05000352/LER-1985-026, :on 850228,spurious half-scram Signal on Reactor Protection Sys Channel a Occurred.Caused by Voltage Fluctuation from Voltage Regulator board.Half-scram Signal Reset & Hoods & Fans Installed + (ML20112D680)
- ML20112D683 + (ML20112D683)
- 05000271/LER-1985-004, :on 850206,backup Generator Lockout Relay 86/GB Energized Causing Turbine Trip & Reactor Scram.Caused by Corrosion on Contacts of Control Switch.Switch Replaced & Core Spray Sys Tested Satisfactorily + (ML20112D688)
- ML20112D692 + (ML20112D692)
- ML20112D696 + (ML20112D696)
- ML20112D699 + (ML20112D699)
- 05000352/LER-1985-023, :on 850205,reactor Encl Equipment Compartment B Exhaust Fan Failed,Resulting in Low Air Flow Rate & Low Differential Pressure.Caused by Loose Pneumatic Fitting on Fan.Fitting Tightened + (ML20112D700)
- ML20112D702 + (ML20112D702)
- ML20112D707 + (ML20112D707)
- 05000282/LER-1985-006, :on 850206,relay Misoperation Caused Lockout of Transformer 10 & auto-start of Diesel Generators.Caused by Bad Connection within Relay.Relay Replaced + (ML20112D708)
- ML20112D711 + (ML20112D711)
- ML20112D721 + (ML20112D721)
- ML20112D725 + (ML20112D725)
- ML20112D729 + (ML20112D729)
- 05000413/LER-1984-030-02, :on 841129,containment Penetration Leak Rate Test Performed Improperly.Caused by Penetration Piping Being Completely Drained.Procedures Revised + (ML20112D731)
- 05000251/LER-1985-005, :on 850207,spurious Safety Injection Signal Generated in ESF Sys W/No Resultant Safety Injection Flow. Caused by Blown Fuse on Flow Comparator of Steam Generator B Coincident W/Electrical Spike.Fuse Replaced + (ML20112D733)
- ML20112D736 + (ML20112D736)
- 05000413/LER-1984-024-02, :on 841124,auxiliary Feedwater Pumps 1A & 1B Started Due to lo-lo Level in Steam Generator 1C.Caused by Personnel Deviating from Procedure.Steam Generator Level Restored & Alarm Cleared + (ML20112D740)
- 05000483/LER-1984-049, :on 841009 & 25,steam Generator B Main Steam Outlet Pressure Indicator & Condensate Storage Tank to Auxiliary Feedwater Pump Suction Header Pressure Indicator Found to Be Outside Tech Spec Limits + (ML20112D741)
- ML20112D744 + (ML20112D744)
- ML20112D748 + (ML20112D748)
- ML20112D751 + (ML20112D751)
- 05000333/LER-1985-005, :on 850206,secondary Containment Integrity Breached During Full Power.Caused by Faulty Latch Mechanism on Outer Door.Mechanism Repaired + (ML20112D752)
- RBG-19-803, Final Deficiency Rept DR-234 Re Short Cap Screws,Shallow Bolt Holes,Damaged Dowel Pins & Damaged or Missing Lock Devices for Hanger Block Bolts in Check Valves Supplied by Velan Engineering,Ltd.Initially Reported on 841128 + (ML20112D753)
- ML20112D760 + (ML20112D760)
- ML20112D764 + (ML20112D764)
- 05000352/LER-1984-028, :on 841209,control Room Chlorine Detector D Failed,Causing Normal Ventilation to Isolate & Train a of Control Room Emergency Fresh Air Sys to Start.Caused by Broken Sample Tape.Tape Repaired + (ML20112D768)
- 05000352/LER-1984-033, :on 841211,failure of Control Room Chlorine Detector D Caused Normal Ventilation to Isolate & Train B of Control Room Emergency Fresh Air Sys to Start.Caused by Broken Sample Tape.Tape Repaired + (ML20112D772)
- RBG-20336, Final Deficiency Rept DR-266 Re Interference Between Bergen Paterson Supplied Clamp Ears & Snubber End Paddle Welds.Final Design of Parts Considered Incomplete.Item Not Reportable Per 10CFR50.55(e) + (ML20112D774)
- ML20112D777 + (ML20112D777)
- RBG-19813, Final Deficiency Rept DR-220 Re Cylinder Heads of Engine Cylinders of Standby Diesel Generators Supplied by Tdi. Initially Reported on 841203.Cylinder Heads Replaced W/New Valve Assemblies + (ML20112D781)
- ML20112D786 + (ML20112D786)
- ML20112D788 + (ML20112D788)
- RBG-19812, Final Deficiency Rept DR-195 Re Insulation for Motors of Valves Supplied by Velan Engineering Ltd.Initially Reported on 841203.Motors Will Be Replaced When Qualified Life of 5 Yrs Expires + (ML20112D795)
- RBG-20325, Final Deficiency Rept DR-213 Re Pressure Setting on Safety Valve Greater than Max Allowable Working Pressure for Air Start Sys Air Receiver Tanks on HPCS Diesel Generator Supplied by Ge.Item Not Reportable Under 10CFR50.55(e) + (ML20112D796)
- ML20112D806 + (ML20112D806)
- RBG-19-802, Final Deficiency Rept DR-232 Re Insulation for Motors of Valves Supplied by Velan Engineering,Ltd.Initially Reported on 841128.Motor Operators Will Be Interchanged by Limitorque Representative + (ML20112D807)
- ML20112D821 + (ML20112D821)
- 05000368/LER-1985-005-02, :on 850207,automatic Reactor Trip Occurred. Caused by Axial Shape Index Out of Range.Procedure Modified to Require Startup Control Element Assembly Positions Be Established Prior to 5% Full Power + (ML20112D832)