- ML20079D624 + (ML20079D624)
- HL-1729, Responds to NRC Re Violations Noted in Insp Rept 50-321/91-13 & 50-366/91-13.Corrective Actions:Involved Personnel Counseled Re Need to Read & Follow All Health Physics Postings & Procedural Requirements + (ML20079D625)
- ML20079D627 + (ML20079D627)
- 05000528/LER-1989-025, :on 891103,discovered That Radiant Energy Fire Barrier Missing from One of Two Pressurizer Auxiliary Spray Valves in Pressurizer Room.Caused by Incomplete Drawings.Engineering Evaluation Underway + (ML20079D629)
- ML20079D641 + (ML20079D641)
- ML20079D648 + (ML20079D648)
- ML20079D650 + (ML20079D650)
- ML20079D652 + (ML20079D652)
- ML20079D655 + (ML20079D655)
- ML20079D658 + (ML20079D658)
- ML20079D668 + (ML20079D668)
- ML20079D670 + (ML20079D670)
- ML20079D671 + (ML20079D671)
- ML20079D680 + (ML20079D680)
- ML20079D681 + (ML20079D681)
- ML20079D683 + (ML20079D683)
- ML20079D684 + (ML20079D684)
- ML20079D685 + (ML20079D685)
- ML20079D686 + (ML20079D686)
- ML20079D688 + (ML20079D688)
- ML20079D690 + (ML20079D690)
- ML20079D691 + (ML20079D691)
- 3F0791-10, Forwards NPDES Repts Inadvertently Omitted as Result of Administrative Oversight + (ML20079D693)
- ML20079D709 + (ML20079D709)
- ML20079D711 + (ML20079D711)
- ML20079D717 + (ML20079D717)
- ML20079D719 + (ML20079D719)
- ML20079D733 + (ML20079D733)
- ML20079D755 + (ML20079D755)
- JPN-91-037, Forwards Response to NRC 901120 Request for Addl Info Re Proposed Changes to Tech Specs on Spent Fuel Pool Storage Capacity.Holtec Rept HI-91614 Encl + (ML20079D758)
- 3F0320-01, NRC Commitment Change Report - March 2020 + (ML20079D765)
- ML20079D771 + (ML20079D771)
- ML20079D772 + (ML20079D772)
- ML20079D788 + (ML20079D788)
- ST-HL-AE-3819, Forwards Rev 17 to Physical Security Plan for Plant.Rev Withheld (Ref 10CFR73.21) + (ML20079D796)
- ML20079D807 + (ML20079D807)
- 05000352/LER-1991-007, :on 910226,determined That Tech Specs Surveillance Requirement Had Not Been Satisfied for Tech Spec Section 3.7.7.Caused by Personnel Error.Appropriate Steps Taken to Satisfy Tech Specs Actions + (ML20079D850)
- 05000425/LER-1991-008-02, :on 910625,train B Safety Injection Pump Tagged Out for Maint.Caused by Procedure Inadequacy.Procedures Will Be Revised to Change Test Methodology + (ML20079D860)
- ML20079D861 + (ML20079D861)
- ML20079D863 + (ML20079D863)
- ML20079D865 + (ML20079D865)
- ML20079D867 + (ML20079D867)
- A09558, Provides Results of Review of Issues Identified Re Activities at Facility (RI-91-A-0049).Issue Does Not Present Indication of Compromise to Nuclear Safety + (ML20079D877)
- 05000456/LER-1988-001-04, :on 880108,train a Control Room Radiation Monitoring Became Inoperable Due to Noisy Pressure Switches. Corrective Action Included Adding Noise Attenuating Filters to Pressure Switch Circuitry + (ML20079D884)
- 05000456/LER-1990-013, :on 900811,feedwater Isolation Occurred Due to Spurious Actuation of Train B Feedwater Isolation Circuitry. Feedwater Isolation Reset & Flow Reestablished to Steam Generators + (ML20079D888)
- 05000266/LER-1991-007, :on 910626,fire Barrier Penetration Seal Discovered Inoperable.Caused by Personnel Error.Fire Watch Stationed & Maintained in Affected Area Until Both Barriers Restored + (ML20079D890)
- 05000353/LER-1991-011-02, :on 910620,plant Personnel Discovered Daily Jet Pump & APRM Flow Unit Operability Verfication Surveillance Test Not Performed.Caused by Personnel Error.Procedures Will Be Revised to Remove Identified Ambiquities + (ML20079D891)
- 05000374/LER-1991-006-06, :on 910321,Unit 2 Primary Containment Integrity Discovered Inoperable.Caused by Procedural Deficiency.Event Tailgated by All Depts Emphasizing That When Requesting Special Procedure,Personnel Be Aware + (ML20079D892)
- 05000338/LER-1991-014, :on 910703,determined That ASME Section XI Surveillance Requirements Inadequately Performed for Four Boric Acid Transfer Pumps During Second Quarter 1991.Caused by Personnel Error.Generic Ltr 89-04 Reviewed + (ML20079D894)
- 05000370/LER-1991-004-05, :on 910422,auxiliary Feedwater Turbine Driven Pump Declared Inoperable.Caused by Mgt & Design Deficiency. Associated Pressure Switches Subsequently Calibr Under Work Request 6010141AE + (ML20079D895)
- 05000374/LER-1991-007-04, :on 910626,control Room Ventilation Charcoal Absorber Actuation Occurred.Due to Inadvertent Bumping During Nearby Maint Activity.Charcoal Absorbers Realigned to Normal Bypass Mode + (ML20079D896)