- L-82-204, Final Deficiency Rept Re Diesel Generator Fuel Oil Day Tank Suction Check Valves,Initially Reported 820217.Valve Springs Removed & Preliminary Tests Performed W/Successful Results + (ML20053C185)
- ML20053C186 + (ML20053C186)
- 05000281/LER-1982-023, Forwards LER 82-023/03L-0 + (ML20053C187)
- ML20053C191 + (ML20053C191)
- ML20053C192 + (ML20053C192)
- 05000302/LER-1982-016-03, /03L-0:on 820304,failed to Properly Complete 10CFR50.59 Review on Planned Mod Resulting in Approval of Mod to Sys That Could Have Allowed Operation W/Response Time Greater than Tech Spec Limit.Caused by Human Error + (ML20053C193)
- 05000267/LER-1982-016-03, /03L-0:on 820427,during Surveillance Testing,Class I Hydraulic Check & Sway Suppressor Snubber CRS-144 Found Inoperable.Caused by Seal & Gasket Leakage Allowing Loss of Hydraulic Oil.Snubber Rebuilt + (ML20053C194)
- 05000206/LER-1981-025, Forwards LER 81-025/01X-1.Detailed Event Analysis Submitted + (ML20053C196)
- 05000281/LER-1982-023-03, /03L-0:on 820420 W/Boric Acid Transfer Pump 1-CH-P-2D Tagged for Maint,Boron Injection Tank Recirculation Lost Due to Failure of 1-CH-P-2C.Caused by Reversal of Slow Speed Motor Leads.Pump Repaired + (ML20053C199)
- 05000259/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20053C200)
- ML20053C202 + (ML20053C202)
- 05000366/LER-1982-037, Forwards LER 82-037/03L-0 + (ML20053C203)
- 05000327/LER-1982-041, Forwards LER 82-041/03L-0 + (ML20053C205)
- ML20053C207 + (ML20053C207)
- ML20053C208 + (ML20053C208)
- ML20053C210 + (ML20053C210)
- 05000259/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20053C213)
- 05000366/LER-1982-037-03, /03L-0:on 820422,insp of RHR Sys Mechanical Snubbers Revealed Disconnected PSA-10 snubbers,2E11-RHR- R351A & B at RHR Loop a Injection Line Inside Drywell.Caused by Preparation for Insulation.Snubbers Reconnected + (ML20053C215)
- 05000327/LER-1982-041-03, /03L-0:on 820317,pressurizer Level Transmitter, 1-LT-68-335,failed to Meet Surveillance Requirements.Caused by Leak in 3-way Valve Manifold Where Loop LT-68-321 Sense Line Tees to Loop 335.Manifold Will Be Replaced + (ML20053C216)
- ML20053C217 + (ML20053C217)
- 05000338/LER-1982-020, Forwards LER 82-020/03L-0 + (ML20053C218)
- 05000259/LER-1982-026-03, /03L-0:on 820422,XR-90-104 Channel C of Windspeed Indication for 887 MSL Elevation Found Inoperable.Caused by Slipping Gear in Tx Instruments Recorder,Model FS11D6D. Recorder Repaired & Returned to Svc + (ML20053C220)
- 05000321/LER-1982-025, Forwards LER 82-025/03L-0 + (ML20053C221)
- 05000327/LER-1982-040, Forwards LER 82-040/03L-0 + (ML20053C224)
- 05000302/LER-1982-033, Forwards LER 82-033/03L-0 + (ML20053C226)
- ML20053C228 + (ML20053C228)
- 05000259/LER-1982-022-03, /03L-0:on 820324,containment Atmosphere Monitor Channel a Would Not Function in Drywell Mode.Caused by Electrical Short in Valcor Model V52630-529-1 Solenoid Assembly FSV76-51 Due to Shorted Bridge Rectifier + (ML20053C230)
- 05000321/LER-1982-025-03, /03L-0:on 820322,while Performing HNP-1-3653, Standby Gas Treatment Sys Failed to Maintain Secondary Containment Integrity.Caused by Leaking Door Seals,Open Drain Valves & Inaccurate Control Room Instruments + (ML20053C231)
- ML20053C232 + (ML20053C232)
- 05000327/LER-1982-040-03, /03L-0:on 820319,loop 2 Temp indicator,1-TI-68-25, for RCS Failed to Meet Surveillance Requirements.Caused by Failure of Temp Modifier Zener Diode Which Allowed Setpoint to Drift Out of Tolerance.Modifier Repaired + (ML20053C234)
- ML20053C235 + (ML20053C235)
- 05000338/LER-1982-020-03, /03L-0:on 820408,containment Gaseous & Particulate Monitors RMS-159-160 Not Property Sealed,Allowing Leakage Into Process Stream.Caused by Deterioration of Canister Cap Seal.Cap Seal Replaced & Alarm Setpoint Readjusted + (ML20053C237)
- 05000324/LER-1982-043, Forwards LER 82-043/03L-0 + (ML20053C238)
- 05000364/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20053C240)
- 05000328/LER-1982-038, Forwards LER 82-038/03L-0 + (ML20053C245)
- ML20053C248 + (ML20053C248)
- 05000364/LER-1982-016-03, /03L-0:on 820330,pressurizer Pressure Fell Below Tech Spec Limit.Caused by Personnel Error in Utilizing Large Borations During Xenon Transients.Personnel Counseled + (ML20053C250)
- 05000328/LER-1982-038-03, /03L-0:on 820318,auxiliary Feedwater Automatic Control Bypass valve,2-LCV-3-171A,failed to Open.Caused by Worn Flapper Nozzle on electro-pneumatic Masoneillon Valve Transducer,Model 8005.Transducer Replaced + (ML20053C253)
- 05000348/LER-1982-021, Forwards LER 82-021/01T-0 + (ML20053C254)
- ML20053C259 + (ML20053C259)
- 05000324/LER-1982-043-03, /03L-0:on 820323, Tripped/Not Available & Abnormal Condition Annunciators for Diesel Generator 3 Received at Rtgb.Caused by Diesel Barrier Gear Limit Switch Actuating/Initiating Lockout Due to Personnel Error + (ML20053C260)
- 0CAN058208, Forwards Corrected Pages to Effluent & Waste Disposal Annual Rept for 1980, in Response to NRC 820423 Request + (ML20053C262)
- ML20053C264 + (ML20053C264)
- 05000302/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20053C266)
- ML20053C271 + (ML20053C271)
- 05000348/LER-1982-021-01, /01T-0:on 820510,while Conducting Shift Turnover & Main Control Board Walkdown,Both Containment Spray Suction Valves from Reactor Water Storage Tank Were Closed.Caused by Operator Error.Valves Opened + (ML20053C272)
- 05000280/LER-1982-041-03, /03L-0:on 820331,during Liquid Waste Release, Radiation Monitor Recorder RR-100 Failed Low.Caused by Dirt Buildup in Drive Motor Stator.Drive Motor Cleaned & Returned to Svc + (ML20053C273)
- ML20053C274 + (ML20053C274)
- PLA-1097, Forwards Addl Info in Response to NRC Concerns Re Chugging Load Definition.Info Will Be Incorporated Into Design Assessment Rept Scheduled for Submittal on 820608 + (ML20053C275)
- ML20053C276 + (ML20053C276)
- 05000302/LER-1982-026-03, /03L-0:on 820326,during Procedural Review, Procedure Identified for Security Sodium Hydroxide Spray in Mode 4 Prior to Entry Into Mode 5,contrary to Tech Specs. Caused by Procedural Error.Procedure Rewritten + (ML20053C279)