Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000266/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G677)
- ML20040G679 + (ML20040G679)
- ML20040G680 + (ML20040G680)
- 05000266/LER-1982-001-03, /03L-0:on 820107,steam Generator Pressure Sensing Lines Discovered Frozen on a Steam Generator.Caused by Inadequate Freeze Protection & Extremely Cold Weather.Addl Heat Lamps Installed + (ML20040G681)
- 05000237/LER-1981-078, Forwards LER 81-078/01X-1 + (ML20040G682)
- ML20040G685 + (ML20040G685)
- 05000237/LER-1981-078-01, /01X-1:on 811223,during Automatic Depressurization Sys Valve Surveillance,Electromatic Relief Valve 2B Failed to Open.Caused by Wire Wedge in Contact That Bypass Hold Coil.Wires Moved + (ML20040G688)
- ML20040G689 + (ML20040G689)
- ML20040G690 + (ML20040G690)
- 05000321/LER-1982-006-01, /01T-0:on 820119,w/facility in Cold Shutdown,Three Pinhole Leaks Found Next to Weld in Flow Element Sensing Line from Recirculation Sys Loop A.Cause Unknown.Failed Section of Sensing Line Replaced.Investigation Underway + (ML20040G691)
- ML20040G693 + (ML20040G693)
- ML20040G694 + (ML20040G694)
- ML20040G695 + (ML20040G695)
- ML20040G696 + (ML20040G696)
- ML20040G698 + (ML20040G698)
- ML20040G700 + (ML20040G700)
- IR 05000322/1982001 + (ML20040G701)
- 05000249/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20040G702)
- ML20040G704 + (ML20040G704)
- 05000270/LER-1982-001, Forwards LER 82-001/01T-0.Detailed Event Analysis Encl + (ML20040G707)
- 05000249/LER-1982-002-03, /03L-0:on 820107,while Local Leak Rate Testing During Refueling Outage,Determined That Outboard MSIVs 3-203-2B & 3-203-2D Were Leaking in Excess of Tech Spec. Caused by Valve Packing Leakage.Packing Tightened + (ML20040G709)
- ML20040G710 + (ML20040G710)
- ML20040G712 + (ML20040G712)
- 05000270/LER-1982-001-01, /01T-0:on 820117,reactor Bldg Equipment Hatch Found Leaking Air Through Gap in Seal.Caused by Personnel Not Verifying Good metal-to-gasket Seal Had Been Made. Procedures Revised to Require Verification of Proper Seal + (ML20040G714)
- ML20040G715 + (ML20040G715)
- 05000155/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G717)
- 05000328/LER-1982-001, Forwards LER 82-001/03L-0 + (ML20040G719)
- 05000155/LER-1982-001-03, /03L-0:on 820111,during Quarterly Test of Reactor Depressurization Sys,Isolation Valve CV4180 Failed to Open, Making One Loop Inoperable.Caused by Valve Stem Seizure. Packing Lubricated & Valve Successfully Tested + (ML20040G722)
- 05000328/LER-1982-001-03, /03L-0:on 820103,ice Condenser Intermediate Deck Door 9.B Discovered Frozen Shut.Caused by Humidity Entering Through Top Deck Blanket Vents,Condensed on I-beams & Dripping Onto Intermediate Deck Door.Ice Removed + (ML20040G723)
- 1CAN028202, Responds to NRC Re Purge Valves.Purge Valve Position Light Is Checked Once During Each 8-h Shift.Locking Screw Installed During Last Refueling Outage to Reduce Problem of Adjusting Screw Backing Out of Proper Position + (ML20040G724)
- ML20040G725 + (ML20040G725)
- 05000328/LER-1982-010, Forwards LER 82-010/03L-0 + (ML20040G727)
- ML20040G729 + (ML20040G729)
- 05000263/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20040G730)
- 05000328/LER-1982-010-03, /03L-0:on 820109,loop 3 Steam Generator Pressure Transmitter 2-PT-1-20A Declared Inoperable.Caused by Frozen Sense Line.Lines Thawed.Similar Incidents Occurred on 820110 & 11 + (ML20040G732)
- ML20040G733 + (ML20040G733)
- ML20040G734 + (ML20040G734)
- ML20040G736 + (ML20040G736)
- 05000263/LER-1982-002-03, /03L-0:on 820107,core Spray Pump 11 Start Time Delay Relay Failed to Operate.Caused by Loose Terminal Connection & Microswitch Contact Burned Open.New GE CR 2820 Relay Installed + (ML20040G737)
- ML20040G739 + (ML20040G739)
- 05000281/LER-1981-081-03, /03L-0:on 811229,containment Isolation Valve, 2-VA-1,found Unlocked,Open & Unattended.Caused by Supervisor Failing to Recognize That Valve Had Been Opened to Allow Venting of C Loop.Valve Closed & Locked + (ML20040G740)
- 05000366/LER-1982-004, Forwards LER 82-004/03L-0 + (ML20040G741)
- ML20040G743 + (ML20040G743)
- 05000281/LER-1981-083-03, /03L-0:on 811231,steam Flow Instruments FI-474 on a Main Stream Line & FI-485 on B Main Stream Line Found Isolated.Caused by Instruments Inadvertently Left Isolated Until Discovery During Startup + (ML20040G745)
- ML20040G746 + (ML20040G746)
- 05000281/LER-1982-003-03, /03L-0:on 820108,PT-27 Revealed Ampere Readings for Heat Tracing Panel 10 Circuits 1B,2A & 5B & Panel 11 Circuit 2A,4C & 5B Found Below Acceptance Criteria.Caused by Excessive Heat.Defective Heat Tracing Replaced & Tested + (ML20040G747)
- 05000366/LER-1982-004-03, /03L-0:on 820112,low Alarm Received on Control Rod Driveline Hydraulic Control Unit 26-47.Caused by Leakage in III Instrument Block Valve of Accumulator. Accumulator Recharged + (ML20040G748)
- ML20040G749 + (ML20040G749)
- ML20040G750 + (ML20040G750)
- ML20040G751 + (ML20040G751)
- ML20040G752 + (ML20040G752)