Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000366/LER-1980-138, Forwards LER 80-138/03L-0 + (ML19345B430)
- ML19345B431 + (ML19345B431)
- 05000366/LER-1980-138-03, /03L-0:on 801027,leakage on Torus Purge Inlet Outboard Isolation Valve 2T48-F324 Found Such That Test Vol Could Not Be Pressurized.Caused by Worn O Rings.Shaft & Housing for O Rings Cleaned.O Rings Replaced + (ML19345B432)
- 05000368/LER-1979-033, Forwards Updated LER 79-033/01X-1 + (ML19345B433)
- ML19345B434 + (ML19345B434)
- ML19345B435 + (ML19345B435)
- ML19345B436 + (ML19345B436)
- 05000318/LER-1980-046, Forwards LER 80-046/03L-0 + (ML19345B437)
- ML19345B438 + (ML19345B438)
- 05000368/LER-1979-033-01, Unisolatable Leak Discovered at Seal Cavity Pressure Sensing Line to 2PT-6006 for Reactor Coolant Pump 2P32A.Caused by Mechanical Fatigue Resulting from Low Stress Cyclic Loading.Mods Complete + (ML19345B439)
- ML19345B441 + (ML19345B441)
- 05000368/LER-1979-067, Forwards Updated LER 79-067/04X-1 + (ML19345B442)
- ML19345B443 + (ML19345B443)
- ML19345B444 + (ML19345B444)
- 05000318/LER-1980-046-03, /03L-0:on 801024,containment Pressure Signal to Reactor Protection Sys Channel a Found Out of Calibr in Nonconservative Direction.Caused by Output of Transmation Isolator 2-E/E-5313A Being 0.2 Vdc Low Over Range + (ML19345B445)
- 05000293/LER-1980-086, Forwards LER 80-086/04L-0 + (ML19345B446)
- ML19345B447 + (ML19345B447)
- 05000293/LER-1980-086-04, /04L-0:on 801024,condenser Delta T Exceeded Tech Spec Limit.Caused by Increasing Sea Water Temp & Lowering Tide Level + (ML19345B449)
- 05000348/LER-1980-065, Forwards LER 80-065/03L-0 + (ML19345B450)
- ML19345B451 + (ML19345B451)
- 05000366/LER-1980-146, Forwards LER 80-146/03L-0 + (ML19345B452)
- ML19345B453 + (ML19345B453)
- 05000339/LER-1980-076, Forwards LER 80-076/03L-0 + (ML19345B454)
- ML19345B455 + (ML19345B455)
- 05000339/LER-1980-083, Forwards LER 80-083/03L-0 + (ML19345B456)
- ML19345B457 + (ML19345B457)
- ML19345B459 + (ML19345B459)
- 05000317/LER-1980-061, Forwards LER 80-061/03L-0 + (ML19345B460)
- ML19345B461 + (ML19345B461)
- 05000366/LER-1980-146-03, /03L-0:on 801029,excessive Noise & Vibration Observed from 1R43-5001B,emergency Diesel Generator.Caused by Scavenging Air Blower.Blower Replaced + (ML19345B462)
- 05000339/LER-1980-076-03, /03L-0:on 801106,steam Generator Level Transmitter LT-486 Gave High Indication of 4.7%.Caused by Instrument Drift.Transmitter Recalibr + (ML19345B463)
- 05000339/LER-1980-083-03, /03L-0:on 801027,F(Q) Limit Exceeded Twice.Caused by Rod Movement at Beginning of Core Life When F(Q) Limit Margins in Core Ctr Are at Min.Power Reduced + (ML19345B465)
- 05000338/LER-1980-096, Forwards LER 80-096/01T-0 + (ML19345B466)
- ML19345B467 + (ML19345B467)
- 05000266/LER-1980-013, Forwards LER 80-013/01T-0 + (ML19345B468)
- ML19345B469 + (ML19345B469)
- 05000348/LER-1980-065-03, /03L-0:on 801022,total Controlled Leakage During Reactor Coolant Pump Seal Controlled Leakage test,FNP-1-STP- 8.0,exceeded Tech Spec Limit.Caused by Failure to Verify Total Flow After Adjustment.Operating Procedure Changed + (ML19345B470)
- 05000317/LER-1980-061-03, /03L-0:on 801024,emergency Diesel Generator 11 Would Not Carry Greater than 2,500 Kw for Greater than 60 Minutes.Caused by High Cylinder Temp Due to Fouling of Injector Tips.Tips Replaced + (ML19345B471)
- 05000368/LER-1979-022, Forwards Updated LER 79-022/99X-1 + (ML19345B472)
- ML19345B473 + (ML19345B473)
- ML19345B475 + (ML19345B475)
- 05000266/LER-1980-013-01, /01T-0:on 801113,suction to 1P4B Boric Acid Transfer Pump Isolated,Rendering Pump Inoperable.Probably Caused by Personnel Error in Returning Valve Lineup to Normal Following Recirculation & Sampling + (ML19345B476)
- 05000338/LER-1980-096-01, /01T-0:on 801114,S&W Determined Significant out-of -phase Transfer Could Occur When Emergency Buses Transferred to Emergency Diesel Generators.Cause Not Determined.Time Delay Circuit Installed on Generators + (ML19345B477)
- 05000254/LER-1980-028, Forwards LER 80-028/03L-0 + (ML19345B478)
- ML19345B479 + (ML19345B479)
- 05000321/LER-1980-111, Forwards LER 80-111/03L-0 + (ML19345B480)
- ML19345B481 + (ML19345B481)
- 05000338/LER-1980-095, Forwards LER 80-095/03L-0 + (ML19345B482)
- ML19345B483 + (ML19345B483)
- 05000271/LER-1980-039, Forwards LER 80-039/03L-0 + (ML19345B484)
- ML19345B485 + (ML19345B485)