LER 80-111/03L-0:on 801106,automatic Depressurization Sys Reactor Water Level Switch 1B21-N042A Actuated Above Tech Specs.Caused by Component Failure Due to Galling of Range Adjusting Screw.Level Switch Replaced
ML19345B495
Person / Time
Site: Hatch 
Issue date: 11/24/1980
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345B495 (2)
Forwards LER 80-111/03L-0
ML19345B480
Person / Time
Site: Hatch 
Issue date: 11/24/1980
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345B480 (1)