- ML19340B194 + (ML19340B194)
- 05000298/LER-1980-034-03, /03L-0:on 800908,during Routine insp,4160-volt Breaker RHR Id Found Not Capable of Closing Automatically. Caused by Failure of GE Magna Blast 4160 Vac Breaker to Charge Rendering Pump Inoperable.Switch Replaced + (ML19340B195)
- ML19340B196 + (ML19340B196)
- 05000327/LER-1980-135-01, Ice Condenser Compartment Temp Exceeded Tech Spec Limit of 27 F.Caused by Ice Condenser Inlet Doors Being Open Due to Differential Pressure Created by Both Lower Compartment Doors Being Open + (ML19340B197)
- IR 05000186/2019202 + (ML19340B199)
- 05000295/LER-1979-095, Forwards LER 79-095/03L-0 + (ML19340B200)
- 05000298/LER-1980-035, Forwards LER 80-035/03L-0 + (ML19340B202)
- ML19340B203 + (ML19340B203)
- 05000293/LER-1980-069-01, /01X-0:on 801007,w/unit at 96% Steady State Power, Reactor Vessel 203-3A Safety Relief Valve Opened.Caused by Excessive Nitrogen Supply Pressure.Pressure Resulted in Leakage Through Solenoid Valve Into Valve Diaphragm + (ML19340B204)
- 05000298/LER-1980-035-03, /03L-0:on 800917,during Surveillance Testing, Gasket in Oil Supply to HPCI Stop Valve Actuator Failed, Causing Shutdown of HPCI Sys.Caused by Gasket of Improper Matl Being Used.Gasket Replaced W/Gasket of Proper Matl + (ML19340B205)
- ML19340B206 + (ML19340B206)
- 05000295/LER-1979-095-03, /03L-0:on 800718,while Performing Axial Power Distribution Monitoring Sys (Apdms) Surveillance w/P250 Computer,Surveillance Frequency Exceeded Tech Spec Limit by 10 Minutes.Caused by Operator Error + (ML19340B207)
- 05000267/LER-1980-050, Forwards LER 80-050/03L-0 + (ML19340B208)
- ML19340B209 + (ML19340B209)
- ML19340B211 + (ML19340B211)
- 05000267/LER-1980-050-03, /03L-0:on 800915,during Piping Audit,Two Hydraulic Snubbers Installed on Class I Piping Were Not Routinely Tested.Caused by Snubbers Omitted from Testing Table Due to Oversight.Procedure Revised + (ML19340B212)
- ML19340B214 + (ML19340B214)
- ML19340B215 + (ML19340B215)
- BSEP-80-1731, Ro:In Reviewing Containment Atmospheric Dilution Sys, Determined Relay in Logic Circuit Does Not Meet FSAR Requirements.Operating Procedures Revised to Include Jumpering of Contacts + (ML19340B216)
- 05000333/LER-1980-076, Forwards LER 80-076/04T-0 + (ML19340B217)
- ML19340B219 + (ML19340B219)
- 05000324/LER-1980-063, Forwards LER 80-063/03L-0 + (ML19340B220)
- ML19340B222 + (ML19340B222)
- ML19340B223 + (ML19340B223)
- 05000333/LER-1980-076-04, /04T-0:on 801002,environ Radiological Monitoring Revealed Activity in Periphyton Organisms Near Site to Be Greater than Ten Times Control Sample for Co-60.Evaluation Does Not Indicate Significant Environ Impact + (ML19340B226)
- ML19340B230 + (ML19340B230)
- 05000324/LER-1980-063-03, /03L-0:on 800918,while Inerting Drywell, Primary Containment Gaseous Analyzer 2-CAC-AT-1259 Found Tracking Improperly.Caused by Instrument Drift.Analyzer Recalibr.Mod Written to Replace Monitors + (ML19340B231)
- ML19340B232 + (ML19340B232)
- 05000295/LER-1980-042, Forwards LER 80-042/03L-0 + (ML19340B233)
- 05000338/LER-1980-084, Forwards LER 80-084/01T-0 + (ML19340B235)
- ML19340B236 + (ML19340B236)
- 05000295/LER-1980-042-03, /03L-0:on 800912,area Monitor for Auxiliary Bldg Heating,Ventilation & Air Conditioning Filter Area Found Reading Erratically & Produced Periodic Alarms.Cause Not Determined.Monitor Functionally Tested & Returned to Svc + (ML19340B238)
- 05000327/LER-1980-113, Forwards LER 80-113/01T-0 + (ML19340B239)
- ML19340B240 + (ML19340B240)
- 05000306/LER-1980-027, Forwards LER 80-027/03L-0 + (ML19340B241)
- ML19340B242 + (ML19340B242)
- ML19340B244 + (ML19340B244)
- 05000338/LER-1980-084-01, /01T-0:on 801002,Westinghouse Notified Util That High Steam Line Flow Setpoints Specified in PLS Document Are Less Conservative than Tech Specs Require.Caused by Calculation Assumptions Not Reflecting Installation + (ML19340B245)
- 05000259/LER-1980-073-01, /01T-0:on 800928,during Steady State Operation, River Water Temp Peaked at 5.1 F Temp Difference.Situation Recurred Next Day.Caused by Incorrect River Temp Rise Predictions.Events Are Random Occurrences + (ML19340B246)
- ML19340B248 + (ML19340B248)
- 05000327/LER-1980-113-01, /01T-0:on 800926,while Exiting Containment Through Upper Containment Airlock,Employee Allowed Inner Door to Slam & Bounce Back.Latch Then Closed Blocking Door Ajar. Caused by Improper Adjustments on Door Operating Mechanism + (ML19340B249)
- 05000344/LER-1980-020, Forwards LER 80-020/01T-0 + (ML19340B251)
- 05000306/LER-1980-027-03, /03L-0:on 800919,steam Flow Transmitter 2FT-474 Found Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter. Transmitter Recalibr.Transmitters Scheduled to Be Replaced + (ML19340B255)
- ML19340B257 + (ML19340B257)
- 05000344/LER-1980-020-01, /01T-0:on 801003,following Reactor Trip,Both Trains of Auxiliary Feedwater Pumps Failed to Respond to Automatic Start Signal.Pumps Were Manually Started.Caused by Incorrectly Wired Slave Relay + (ML19340B258)
- ML19340B261 + (ML19340B261)
- ML19340B263 + (ML19340B263)
- 05000293/LER-1980-068, Forwards LER 80-068/03L-0 + (ML19340B264)
- ML19340B265 + (ML19340B265)
- ML19340B266 + (ML19340B266)
- 05000293/LER-1980-067, Forwards LER 80-067/01T-0 + (ML19340B267)