List of results
- ML19256E454 + (ML19256E454)
- ML19256E455 + (ML19256E455)
- ML19256E458 + (ML19256E458)
- ML19256E459 + (ML19256E459)
- ML19256E460 + (ML19256E460)
- ML19256E461 + (ML19256E461)
- ML19256E462 + (ML19256E462)
- ML19256E463 + (ML19256E463)
- ML19256E464 + (ML19256E464)
- ML19256E465 + (ML19256E465)
- ML19256E466 + (ML19256E466)
- ML19256E467 + (ML19256E467)
- ML19256E468 + (ML19256E468)
- ML19256E469 + (ML19256E469)
- ML19256E470 + (ML19256E470)
- 05000317/LER-1979-055, Forwards LER 79-055/03L-0 + (ML19256E471)
- ML19256E472 + (ML19256E472)
- 05000317/LER-1979-055-03, /03L-0:on 790930,channel a Lower Positive Power Distribution Setpoint Found Decreasing.Caused by end-of-life Type Failure of Adjustment Potentiometer of Dual Potentiometer/Buffer Module Model 384612-01 + (ML19256E473)
- 05000295/LER-1979-077, Forwards LER 79-077/01T-0 + (ML19256E474)
- ML19256E476 + (ML19256E476)
- 05000295/LER-1979-077-01, /01T-0:on 791016,cracks Identified in Steam Generator Feedwater Nozzles & Associated Piping.Will Remove One Nozzle for Examination.Updated LER to Be Submitted 30 Days Following Test + (ML19256E477)
- 05000324/LER-1979-085, Forwards LER 79-085/03L-0 + (ML19256E480)
- ML19256E481 + (ML19256E481)
- 05000338/LER-1979-122-31, /03L-0:on 790919,during Normal Operation,Steam Generator C Support Temp Fell Below Tech Specs Limit of 225 F.Caused by Personnel Failure to Recognize Low Support Temp Until Temp Exceeded.Support Heaters Energized + (ML19256E482)
- 05000302/LER-1979-096, Forwards LER 79-096/01T-0 + (ML19256E483)
- ML19256E484 + (ML19256E484)
- 05000324/LER-1979-085-03, /03L-0:on 790918,suppression Pool Water Temp Recorder on Remote Shutdown Panel Discovered Inoperable. Relay K-3 Dirty & Not Making Good Contact.Contacts Burnished & Recorder Returned to Svc + (ML19256E486)
- 05000336/LER-1979-032, Forwards LER 79-032/03L-0 + (ML19256E487)
- ML19256E488 + (ML19256E488)
- 05000309/LER-1979-024, Forwards LER 79-024/99X-0 + (ML19256E489)
- ML19256E491 + (ML19256E491)
- 05000336/LER-1979-032-03, /03L-0:on 791002,during Repairs to Metrascope, Control Element Assemblies 6 & 7 in Shutdown Group B Indicated Low Readings.Caused by Faulty Input Amplifiers. Metrascope re-energized + (ML19256E493)
- ML19256E494 + (ML19256E494)
- 05000309/LER-1979-024-99, /99X-0:on 791017,reactor Coolant Dose Equivalent Iodine Exceeded Tech Spec Limits of 1.0 Uci/G.Caused by Unscheduled Plant Trip.Monitoring Program Established Following Trip to Adhere to Iodine Trends + (ML19256E495)
- ML19256E496 + (ML19256E496)
- 05000302/LER-1979-096-01, /01T-0:on 790780,vol of Sodium Hydroxide Tank Exceeded Tech Spec,But Not Reported.Caused by Inadequate Design.Daily Operating Surveillance Procedure SP-300 Revised to Include Operating Band Requirement + (ML19256E497)
- ML19256E498 + (ML19256E498)
- ML19256E499 + (ML19256E499)
- 05000317/LER-1979-063, Forwards LER 79-063/04T-0 + (ML19256E500)
- ML19256E501 + (ML19256E501)
- ML19256E502 + (ML19256E502)
- 05000265/LER-1979-022, Forwards LER 79-022/03L-0 + (ML19256E503)
- ML19256E504 + (ML19256E504)
- 05000265/LER-1979-022-03, /03L-0:on 791005,vacuum Breaker AO 2-1601-32B Failed to Give Full Open Red Light Indication.Caused by Valve Position Indicating Switch Problem.Corrective Actions to Be Completed During Nov 1979 Refueling Outage + (ML19256E505)
- 05000249/LER-1979-027, Forwards LER 79-027/03L-0 + (ML19256E506)
- 05000317/LER-1979-063-04, /04T-0:on 791022,presence of Ag-110m Detected in Camp Canoy Oyster Samples.Caused by Fluctuations in Plant Operation.Procedure Mods & Personnel Reinstruction Instituted + (ML19256E507)
- ML19256E508 + (ML19256E508)
- ML19256E509 + (ML19256E509)
- ML19256E510 + (ML19256E510)
- ML19256E511 + (ML19256E511)
- ML19256E512 + (ML19256E512)