Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17266A321 + (ML17266A321)
- ML17266A322 + (ML17266A322)
- ML17266A323 + (ML17266A323)
- ML17266A324 + (ML17266A324)
- ML17266A325 + (ML17266A325)
- ML17266A326 + (ML17266A326)
- ML17266A327 + (ML17266A327)
- ML17266A328 + (ML17266A328)
- ML17266A329 + (ML17266A329)
- ML17266A330 + (ML17266A330)
- ML17266A331 + (ML17266A331)
- ML17266A332 + (ML17266A332)
- ML17266A333 + (ML17266A333)
- ML17266A334 + (ML17266A334)
- ML17266A335 + (ML17266A335)
- ML17266A336 + (ML17266A336)
- ML17266A337 + (ML17266A337)
- ML17266A338 + (ML17266A338)
- ML17266A339 + (ML17266A339)
- ML17266A340 + (ML17266A340)
- ML17266A341 + (ML17266A341)
- ML17266A342 + (ML17266A342)
- ML17266A343 + (ML17266A343)
- ML17266A344 + (ML17266A344)
- ML17266A345 + (ML17266A345)
- ML17266A346 + (ML17266A346)
- ML17266A347 + (ML17266A347)
- ML17266A348 + (ML17266A348)
- ML17266A349 + (ML17266A349)
- ML17266A350 + (ML17266A350)
- ML17266A351 + (ML17266A351)
- ML17266A352 + (ML17266A352)
- L-81-369, Forwards Responses to NRC Requests for Addl Info Re Facility.Responses Will Be Incorporated in Future FSAR Amend.Ten Oversize Drawings Encl.Aperture Cards Are Available in PDR + (ML17266A353)
- ML17266A354 + (ML17266A354)
- ML17266A355 + (ML17266A355)
- ML17266A356 + (ML17266A356)
- L-80-338, Forwards Financial Info Requested by NRC Re Transfer of Ownership Interest to City of Orlando & Orlando Utils Commission.Cash Flow Statement & Bond Info Encl + (ML17266A357)
- 05000335/LER-1980-060-03, /03L-0:on 800929,design Review of Unit 2 Determined Tie Line Between Condensate Storage Tank & Unit 1 Auxiliary Feedwater Did Not Meet Intent of Design.Caused by Design Error.Tie Line to Be Modified + (ML17266A358)
- L-80-365, Final Deficiency Rept Originally Reported on 800325 Re Defective Hydramotor Actuators for Dampers & Louvers.Caused by Mfg from Incorrect Matl.Dampers Reworked & Retested. Dampers & Louvers to Be Tested in Preoperational Program + (ML17266A359)
- ML17266A361 + (ML17266A361)
- L-80-381, Application to Amend License DPR-67 by Upgrading Rated Power from 2,560 MW to 2,700 Mw.Forwards Proposed Tech Spec Changes & Supporting Matl + (ML17266A362)
- ML17266A363 + (ML17266A363)
- ML17266A364 + (ML17266A364)
- 05000335/LER-1980-059-03, /03L-0:on 801024,primary Ddps Computer Failed, Causing Loss of Control Element Assembly Position Indication.Caused by Program Software Error.Position Info Manually Reloaded Into Backup Computer + (ML17266A365)
- 05000335/LER-1980-046-03, While at 100% Power, Control Element Assembly 33 Dropped to Fully Inserted Position.Caused by Failed 15-volt Dc Power Supply in Coil Power Programmer.Power Supply Replaced + (ML17266A366)
- 05000335/LER-1979-014-09, Diesel Generator Vendor Notified Util of Potential Failure of Crankshaft Coupling for Cooling Fans on Diesel Generators.Cause Unstated. Couplings Replaced W/Couplings of Improved Design + (ML17266A367)
- 05000335/LER-1980-057-03, /03L-0:on 801008,3-inch Rip Noted in Fire Hose & Equivalent Capacity Hose Not Routed to Unprotected Area within 1-h.Caused by Procedural Deficiency.Procedure Modified + (ML17266A368)
- 05000335/LER-1980-058-03, /03L-0:on 801019,target A-16 Alarmed (Diesel Generator 1B Failure to Start).Caused by Open Feeder Breaker to PP-112.Feeder Breaker Closed + (ML17266A369)
- ML17266A370 + (ML17266A370)
- 05000335/LER-1980-061-03, /03L-0:on 801027,dc Electric Buses Were Switched Into Configuration Such That One Dc Bus Provided Control Power for Both Component Cooling Water Loops.Caused by Electrical Maint Activity + (ML17266A371)
- 05000335/LER-1980-043-03, /03L-0:on 800821,during Normal Operation,Cedm 39 Failed,Dropping CEA to Full Insertion.Cause of Failure Undetermined.Power Supply Unit Replaced.Cedm 39 Returned to Normal Operations + (ML17266A372)