Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +, ML20217D756 +...
October 1, 1997 +
IR 05000302/1996012 +, 05000302/LER-1989-009, Submits Justification for Restart of Plant as Committed to in LER 89-009.Based on Test & Insp Data,Util Has Determined That Continued Operation W/Existing DHR Pumps Will Not Pose Unresolved Safety Concerns +, 3F0789-04, Forwards MPR-1134, Evaluation of Crystal River Unit 3 Decay Heat Pump at Low Flow Operation & Supplemental Response to Bulletin 88-004.Suggests Meeting W/Nrc Be Planned for No Later than 890811 to Discuss Rept +, 3F0689-07, Application for Amend to License DPR-72,consisting of Tech Spec Change Request 168,adding New Spec to Address Use of Hydrogen Purge Valves for Depressurization +, 3F0597-08, Forwards Info Necessary for NRC Closure of Uresolved Item URI-96-201-01,identified in Ltr & Addresses LPI Pump Mission Time.Proprietary Info Encl.Proprietary Info Withheld + and ML20259D651 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
14:07:40, 3 December 2024 +
6 +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
Approval +
October 1, 1997 +
Safety Evaluation Concluding That Testing of Ingersoll-Dresser Pump Model 8HN194 at Test Facility Demonstrates That Crystal River Decay Heat Pumps of Same Model Can Operate at Flows of 100 Gpm for 30 Days +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.