Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +, L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +  and L-81-443, Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable +
October 8, 1981  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
18:33:03, 20 December 2024  +
October 8, 1981  +
Final Deficiency Rept Re Linear Indication Observed in Reactor Coolant 3/4-inch Schedule 160,304 SS Pipe,Initially Reported on 810909.Linear Indication Determined to Be Hot Mill Seam.Pipe Replaced.Incident Determined Not Reportable  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.