Browse wiki
Jump to navigation
Jump to search
The following information was provided by … The following information was provided by the Ohio Department of Health via email:</br>On January 28, 2025, the Ohio Department of Health, Bureau of Environmental Health and Radiation Protection was notified by University Hospitals of Cleveland that during a therapeutic infusion of Pluvicto (Lu-177) (that was administered on January 27, 2025), 60.9 mCi of a total dose of 295 mCi was extravasated in the patient's right arm antecubital area (i.e. not the intended treatment site). The licensee calculated a 0.61 Gy dose to the skin near the extravasation site based on imaging taken from 20 minutes to 22 hours post-infusion. At 22 hours post infusion, 0.46 mCi remained around the injection site based on imaging. The authorized user believes the material has drained through the lymphatic system to the prostate.</br>Ohio Item Number: OH250001</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
05:00:00, 27 January 2025 +
12:51:00, 29 January 2025 +
05:00:00, 27 January 2025 +
The following information was provided by … The following information was provided by the Ohio Department of Health via email:</br>On January 28, 2025, the Ohio Department of Health, Bureau of Environmental Health and Radiation Protection was notified by University Hospitals of Cleveland that during a therapeutic infusion of Pluvicto (Lu-177) (that was administered on January 27, 2025), 60.9 mCi of a total dose of 295 mCi was extravasated in the patient's right arm antecubital area (i.e. not the intended treatment site). The licensee calculated a 0.61 Gy dose to the skin near the extravasation site based on imaging taken from 20 minutes to 22 hours post-infusion. At 22 hours post infusion, 0.46 mCi remained around the injection site based on imaging. The authorized user believes the material has drained through the lymphatic system to the prostate.</br>Ohio Item Number: OH250001</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 30 January 2025 +
02110180077 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:20:20, 1 January 2026 +
12:51:00, 29 January 2025 +
2.327 d (55.85 hours, 0.332 weeks, 0.0765 months) +
05:00:00, 27 January 2025 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.