The following information was provided by The following information was provided by the Texas A&M University (TAMN) via phone and email:</br>At approximately 1315 CDT on Wednesday, June 28, 2023, during routine fuel inspections required under Technical Specification (TS) 4.1.5 ('Reactor Fuel Elements'), a fuel pin (serial number 11394) did not pass the test criteria. The pin was bloated enough to not fit in the bend test rig. This meets the definition of a `Reportable Occurrence' under the definitions in TS 1.3. In accordance with the requirements of TS 6.6.2 and 6.7.2, TAMN notified the NRC Headquarters Operations Officer within one working day.</br>Visual inspection of the pin did not indicate any obvious degradation that would be exceptional for a pin with sixteen years of burnup history, other than a slight bloat in the middle of the pin.</br>There have been no indications of cladding failure on routine primary coolant analyses.</br>As required by TS 4.1.5.2, TAMN is initiating an inspection of the entire core fuel inventory once TAMN finishes the regularly scheduled fuel inspections for the year. TAMN informed the NRC Project Manager.e year. TAMN informed the NRC Project Manager.  +
18:15:00, 28 June 2023  +
56,595  +
10:20:00, 29 June 2023  +
18:15:00, 28 June 2023  +
The following information was provided by The following information was provided by the Texas A&M University (TAMN) via phone and email:</br>At approximately 1315 CDT on Wednesday, June 28, 2023, during routine fuel inspections required under Technical Specification (TS) 4.1.5 ('Reactor Fuel Elements'), a fuel pin (serial number 11394) did not pass the test criteria. The pin was bloated enough to not fit in the bend test rig. This meets the definition of a `Reportable Occurrence' under the definitions in TS 1.3. In accordance with the requirements of TS 6.6.2 and 6.7.2, TAMN notified the NRC Headquarters Operations Officer within one working day.</br>Visual inspection of the pin did not indicate any obvious degradation that would be exceptional for a pin with sixteen years of burnup history, other than a slight bloat in the middle of the pin.</br>There have been no indications of cladding failure on routine primary coolant analyses.</br>As required by TS 4.1.5.2, TAMN is initiating an inspection of the entire core fuel inventory once TAMN finishes the regularly scheduled fuel inspections for the year. TAMN informed the NRC Project Manager.e year. TAMN informed the NRC Project Manager.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 29 June 2023  +
R-83  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:30:13, 3 July 2023  +
10:20:00, 29 June 2023  +
Processing error"Processing error" is a predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> and represents errors that appeared in connection with improper value annotations or input processing.
0.67 d (16.08 hours, 0.0957 weeks, 0.022 months)  +
18:15:00, 28 June 2023  +
Technical Specifications Deviation - Degraded Fuel Pin  +