Browse wiki
Jump to navigation
Jump to search
The following information was received fro … The following information was received from the state of Colorado via facsimile:</br>On June 24, 2022, a patient was prescribed 1.45 GBq (39.2 mCi) of Y-90 microspheres (TheraSphere) to the right lobe of the liver, lobe estimated size of 474 grams, for a target dose of 148 Gy. However, imaging after the administration indicates that the dose was incorrectly delivered to the left lobe of the liver, lobe estimated size of 283 grams, for an estimated delivered dose of 240 Gy. The preliminary cause is based on the patient's anatomy with the left hepatic branch close to the intended treatment site. The physician's office is reaching out to the patient to notify them but has not been able to at the time of this initial notification.</br>Colorado Event Report ID No.: CO220019</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
06:00:00, 24 June 2022 +
17:07:00, 27 June 2022 +
06:00:00, 24 June 2022 +
The following information was received fro … The following information was received from the state of Colorado via facsimile:</br>On June 24, 2022, a patient was prescribed 1.45 GBq (39.2 mCi) of Y-90 microspheres (TheraSphere) to the right lobe of the liver, lobe estimated size of 474 grams, for a target dose of 148 Gy. However, imaging after the administration indicates that the dose was incorrectly delivered to the left lobe of the liver, lobe estimated size of 283 grams, for an estimated delivered dose of 240 Gy. The preliminary cause is based on the patient's anatomy with the left hepatic branch close to the intended treatment site. The physician's office is reaching out to the patient to notify them but has not been able to at the time of this initial notification.</br>Colorado Event Report ID No.: CO220019</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 27 June 2022 +
CO 305-03 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:30:34, 6 July 2022 +
17:07:00, 27 June 2022 +
3.463 d (83.12 hours, 0.495 weeks, 0.114 months) +
06:00:00, 24 June 2022 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.