Browse wiki

Jump to navigation Jump to search
The following is a summary of a phone callThe following is a summary of a phone call with the licensee: </br>On 7/30/2021 while at the jobsite in Moca, Puerto Rico, the licensee's InstroTek MC-3 Elite gauge was run over by a paving roller while in the safety drum. The gauge plastic casing was damaged and the source rod was broken. The sources were in the shielded position at the time of the incident. The InstroTek gauge serial number is 31331 and contains nominally 10 mCi of Cs-137 and 50 mCi of AmBe.</br>The damaged gauge was placed in its storage container and returned to the licensee's Cabo Rojo facility for a swipe test. After the incident, the gauge read 0.2 to 0.3 mR/hr at 1 meter with a survey meter.</br>No overexposures were reported. </br>* * * RETRACTION ON 8/3/21 AT 1320 EDT FROM ALFONSO BOSQUE TO KERBY SCALES * * *</br>The following retraction is a summary of a phone call with the licensee:</br>The Radiation Safety Officer inspected the gauge and verified that the gauge maintained its safety function. The source was secured and a leak test verified no leakage.</br>Notified R1DO (Eve) and NMSS Event Notification via email.ve) and NMSS Event Notification via email.  +
17:05:00, 30 July 2021  +
55,388  +
15:43:00, 30 July 2021  +
17:05:00, 30 July 2021  +
The following is a summary of a phone callThe following is a summary of a phone call with the licensee: </br>On 7/30/2021 while at the jobsite in Moca, Puerto Rico, the licensee's InstroTek MC-3 Elite gauge was run over by a paving roller while in the safety drum. The gauge plastic casing was damaged and the source rod was broken. The sources were in the shielded position at the time of the incident. The InstroTek gauge serial number is 31331 and contains nominally 10 mCi of Cs-137 and 50 mCi of AmBe.</br>The damaged gauge was placed in its storage container and returned to the licensee's Cabo Rojo facility for a swipe test. After the incident, the gauge read 0.2 to 0.3 mR/hr at 1 meter with a survey meter.</br>No overexposures were reported. </br>* * * RETRACTION ON 8/3/21 AT 1320 EDT FROM ALFONSO BOSQUE TO KERBY SCALES * * *</br>The following retraction is a summary of a phone call with the licensee:</br>The Radiation Safety Officer inspected the gauge and verified that the gauge maintained its safety function. The source was secured and a leak test verified no leakage.</br>Notified R1DO (Eve) and NMSS Event Notification via email.ve) and NMSS Event Notification via email.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 3 August 2021  +
52-35550-01  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:30:17, 9 August 2021  +
15:43:00, 30 July 2021  +
-0.0571 d (-1.37 hours, -0.00815 weeks, -0.00188 months)  +
true  +
17:05:00, 30 July 2021  +
Damaged Instrotek Moisture Density Gauge  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.