The following information was received froThe following information was received from the State of Arizona via email:</br>During a routine inspection, the Arizona Radiation Regulatory Agency discovered that the handle locking mechanism of a CPN MC-3 Portaprobe (Serial # M39068944) containing 370MBq (10mCi) of Cesium-137 and 1.85 GBq (50mCi) of Americium-241/Beryllium, failed to function as intended. While testing the locking mechanism, the inspector was able to lower the Cs-137 source out of its housing, exposing the source, while the handle and trigger were in the locked position. The licensee was notified and the gauge was immediately placed out of service. The utilization log for the gauge was checked and it was determined that the gauge had not been in use for the previous 6 months. None of the users had reported issues with the gauge prior to that time. The licensee committed to having the gauge serviced as soon as possible.</br>The Agency (Arizona Radiation Regulatory Agency) is continuing to investigate the event.</br>The (Arizona) Governor's office and U.S. NRC are being notified of this event.</br>(Arizona) First Notice: 17-011his event. (Arizona) First Notice: 17-011  +
22:00:00, 2 August 2017  +
52,883  +
18:53:00, 2 August 2017  +
22:00:00, 2 August 2017  +
The following information was received froThe following information was received from the State of Arizona via email:</br>During a routine inspection, the Arizona Radiation Regulatory Agency discovered that the handle locking mechanism of a CPN MC-3 Portaprobe (Serial # M39068944) containing 370MBq (10mCi) of Cesium-137 and 1.85 GBq (50mCi) of Americium-241/Beryllium, failed to function as intended. While testing the locking mechanism, the inspector was able to lower the Cs-137 source out of its housing, exposing the source, while the handle and trigger were in the locked position. The licensee was notified and the gauge was immediately placed out of service. The utilization log for the gauge was checked and it was determined that the gauge had not been in use for the previous 6 months. None of the users had reported issues with the gauge prior to that time. The licensee committed to having the gauge serviced as soon as possible.</br>The Agency (Arizona Radiation Regulatory Agency) is continuing to investigate the event.</br>The (Arizona) Governor's office and U.S. NRC are being notified of this event.</br>(Arizona) First Notice: 17-011his event. (Arizona) First Notice: 17-011  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 2 August 2017  +
AZ 07-662  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:51:19, 24 November 2018  +
18:53:00, 2 August 2017  +
-0.13 d (-3.12 hours, -0.0186 weeks, -0.00427 months)  +
22:00:00, 2 August 2017  +
Agreement State Report - Failed Nuclear Moisture/Density Gauge Handle Locking Mechanism  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.