Browse wiki
Jump to navigation
Jump to search
The following information was received via … The following information was received via facsimile:</br>On February 13, 2017, the Department (PA DEP Bureau of Radiation Protection) was notified by Universal Well Services that a malfunction of a roll pin on a shutter handle occurred at a temporary job site in Zelienople, Pennsylvania. It is initially reportable per 10 CFR 30.50(b)(2).</br>A roll pin, which holds the shutter handle to the shutter shaft, on one of the in-line density gauges became sheared off during an attempt to move the shutter to the open position, rendering the gauge unusable. The shutter is in the closed position and out-of-service awaiting repair from a service provider. No exposures occurred.</br>The shutter is in the closed position and the gauge is out-of-service and secure. There was no other damage to the gauge. A reactive inspection is planned by the Department.</br>The gauge was a Berthold, Model LB 8010, Serial Number 10055, containing 20 mCi of Cs-137.</br>Pennsylvania Event Report ID No.: PA170002ennsylvania Event Report ID No.: PA170002 +
05:00:00, 6 February 2017 +
14:17:00, 14 February 2017 +
05:00:00, 6 February 2017 +
The following information was received via … The following information was received via facsimile:</br>On February 13, 2017, the Department (PA DEP Bureau of Radiation Protection) was notified by Universal Well Services that a malfunction of a roll pin on a shutter handle occurred at a temporary job site in Zelienople, Pennsylvania. It is initially reportable per 10 CFR 30.50(b)(2).</br>A roll pin, which holds the shutter handle to the shutter shaft, on one of the in-line density gauges became sheared off during an attempt to move the shutter to the open position, rendering the gauge unusable. The shutter is in the closed position and out-of-service awaiting repair from a service provider. No exposures occurred.</br>The shutter is in the closed position and the gauge is out-of-service and secure. There was no other damage to the gauge. A reactive inspection is planned by the Department.</br>The gauge was a Berthold, Model LB 8010, Serial Number 10055, containing 20 mCi of Cs-137.</br>Pennsylvania Event Report ID No.: PA170002ennsylvania Event Report ID No.: PA170002 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 14 February 2017 +
PA-1446 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:52:33, 24 November 2018 +
14:17:00, 14 February 2017 +
8.387 d (201.28 hours, 1.198 weeks, 0.276 months) +
05:00:00, 6 February 2017 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.