Browse wiki

Jump to navigation Jump to search
The following was received from the State The following was received from the State of Texas via email:</br>On December 10, 2016, the Agency (Texas Department of State Health Services) was notified that on December 9, 2016, the licensee (while working at Exxon Mobil in Beaumont, Texas) was required to perform a source retrieval of a 74.9 curie iridium-192 source. The exposure device associated with the source is a QSA 880 exposure device. The licensee reported the exposure device fell on the guide tube and crimped it to a point where the source could not pass by. The radiographers verified their boundaries and contacted their radiation safety officer. The licensee sent a qualified recovery team to the location. The recovery team cut the guide tube and was able to retract the source. No individual received an exposure that exceeded any limits. No member of the general public was exposed as a result of this event. The licensee stated the camera would be sent to the manufacturer for inspection. The licensee stated they would provide additional information on December 13, 2016. Additional information will be provided as it is received in accordance with SA-300.</br>Texas Incident #: I - 9447ce with SA-300. Texas Incident #: I - 9447  +
06:00:00, 9 December 2016  +
52,424  +
11:12:00, 10 December 2016  +
06:00:00, 9 December 2016  +
The following was received from the State The following was received from the State of Texas via email:</br>On December 10, 2016, the Agency (Texas Department of State Health Services) was notified that on December 9, 2016, the licensee (while working at Exxon Mobil in Beaumont, Texas) was required to perform a source retrieval of a 74.9 curie iridium-192 source. The exposure device associated with the source is a QSA 880 exposure device. The licensee reported the exposure device fell on the guide tube and crimped it to a point where the source could not pass by. The radiographers verified their boundaries and contacted their radiation safety officer. The licensee sent a qualified recovery team to the location. The recovery team cut the guide tube and was able to retract the source. No individual received an exposure that exceeded any limits. No member of the general public was exposed as a result of this event. The licensee stated the camera would be sent to the manufacturer for inspection. The licensee stated they would provide additional information on December 13, 2016. Additional information will be provided as it is received in accordance with SA-300.</br>Texas Incident #: I - 9447ce with SA-300. Texas Incident #: I - 9447  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 10 December 2016  +
01774  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:15:55, 24 September 2017  +
11:12:00, 10 December 2016  +
1.217 d (29.2 hours, 0.174 weeks, 0.04 months)  +
06:00:00, 9 December 2016  +
Agreement State Report - Radiography Source Could Not Be Retracted  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.