Browse wiki

Jump to navigation Jump to search
The following report was received from theThe following report was received from the North Carolina Department of Health and Human Services via email:</br>The Agency (North Carolina Department of Health and Human Services) was notified of service contract reciprocity 0003-R Ronan to arrive at NC (North Carolina) Licensee Chemours in Fayetteville on 9/21/16. Ronan to work on a Ronan SA-1, Gauge SN:M1713, Cs-137, 20 mCi (decayed to approx 10 mCi) with a stuck shutter.</br>(The North Carolina Radioactive Materials Branch Health Physicist) went to Chemours 0109-7 to conduct a reciprocity inspection, and conducted an investigation regarding (Chemours) failing to notify the Agency (North Carolina Department of Health and Human Services) of a stuck shutter on a radioactive gauge. The stuck shutter was identified during scheduled leak test and shutter testing by Chemours workers in June, 2016. This was confirmed with the RSO (Radiation Safety Officer). </br>Shutter was in the open position. No members of the public or workers were at risk of exposure (due to facility design).</br>Source: Cs-137</br>Activity: 0.020 Ci</br>Manufacturer: Ronan Engineering</br>Model Number: sa-1</br>Serial Number: m1713</br>NC Item Number: NC160030l Number: m1713 NC Item Number: NC160030  +
04:00:00, 20 April 2016  +
52,257  +
17:56:00, 22 September 2016  +
04:00:00, 20 April 2016  +
The following report was received from theThe following report was received from the North Carolina Department of Health and Human Services via email:</br>The Agency (North Carolina Department of Health and Human Services) was notified of service contract reciprocity 0003-R Ronan to arrive at NC (North Carolina) Licensee Chemours in Fayetteville on 9/21/16. Ronan to work on a Ronan SA-1, Gauge SN:M1713, Cs-137, 20 mCi (decayed to approx 10 mCi) with a stuck shutter.</br>(The North Carolina Radioactive Materials Branch Health Physicist) went to Chemours 0109-7 to conduct a reciprocity inspection, and conducted an investigation regarding (Chemours) failing to notify the Agency (North Carolina Department of Health and Human Services) of a stuck shutter on a radioactive gauge. The stuck shutter was identified during scheduled leak test and shutter testing by Chemours workers in June, 2016. This was confirmed with the RSO (Radiation Safety Officer). </br>Shutter was in the open position. No members of the public or workers were at risk of exposure (due to facility design).</br>Source: Cs-137</br>Activity: 0.020 Ci</br>Manufacturer: Ronan Engineering</br>Model Number: sa-1</br>Serial Number: m1713</br>NC Item Number: NC160030l Number: m1713 NC Item Number: NC160030  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 22 September 2016  +
026-0109-7  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:16:08, 24 September 2017  +
17:56:00, 22 September 2016  +
155.58 d (3,733.93 hours, 22.226 weeks, 5.115 months)  +
04:00:00, 20 April 2016  +
Agreement State Report - Nuclear Gauge Stuck Shutter  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.