The following information was received fro … The following information was received from the State of Texas via email:</br>On July 6, 2016, the licensee reported to the Agency (Texas Department of State Health Services) that one of its moisture density gauges had been run over and damaged, a Troxler Model 3411 containing 10 millicurie cesium-137 source and a 40 millicurie americium-241/beryllium source, serial number 10471 (at a highway construction site near Robstown, TX). The technician had started the test and the source rod was extended into the ground. While the test was in progress the step-up grader hit the gauge, causing the source rod to bend. The technician stopped all work at the jobsite and setup a boundary of fifteen feet because the source rod could not be retracted. The technician called the RSO (Radiation Safety Officer) and RSO contacted a service company, Qual-Tek, to respond to the site to retrieve the gauge. The site foreman moved the road crew down the highway to avoid the gauge. The technician will stay at the site near the gauge until it is collected by Qual-Tek. (The RSO is investigating.) No member of the public or worker received any exposure as a result of this event. An update will be provided as obtained in accordance with SA300.</br>Texas Incident: I-9417ordance with SA300.
Texas Incident: I-9417 +
05:00:00, 6 July 2016 +
52,066 +
11:27:00, 6 July 2016 +
05:00:00, 6 July 2016 +
The following information was received fro … The following information was received from the State of Texas via email:</br>On July 6, 2016, the licensee reported to the Agency (Texas Department of State Health Services) that one of its moisture density gauges had been run over and damaged, a Troxler Model 3411 containing 10 millicurie cesium-137 source and a 40 millicurie americium-241/beryllium source, serial number 10471 (at a highway construction site near Robstown, TX). The technician had started the test and the source rod was extended into the ground. While the test was in progress the step-up grader hit the gauge, causing the source rod to bend. The technician stopped all work at the jobsite and setup a boundary of fifteen feet because the source rod could not be retracted. The technician called the RSO (Radiation Safety Officer) and RSO contacted a service company, Qual-Tek, to respond to the site to retrieve the gauge. The site foreman moved the road crew down the highway to avoid the gauge. The technician will stay at the site near the gauge until it is collected by Qual-Tek. (The RSO is investigating.) No member of the public or worker received any exposure as a result of this event. An update will be provided as obtained in accordance with SA300.</br>Texas Incident: I-9417ordance with SA300.
Texas Incident: I-9417 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 6 July 2016 +
01571 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:16:23, 24 September 2017 +
11:27:00, 6 July 2016 +
0.269 d (6.45 hours, 0.0384 weeks, 0.00884 months) +
05:00:00, 6 July 2016 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.