The following was received from the State The following was received from the State of Tennessee via email:</br>A fire occurred in an off gas dust collector and particulate filtration system used for ventilation from a process providing oxidation of metal depleted uranium chips. Alarm engaged and fire suppression system engaged. The local fire department responded and reinforced suppression. The fire department departed by 11:20 AM. Initial indications indicate no releases to the environment based on visual indications and stack monitoring systems not alarming. Negative pressure to the building was maintained. Smears taken outside of the building and radiologically controlled area does not indicate any elevated activity outside of the building. Air samples are being pulled and analyzed for workplace and air effluent stacks. Bioassays were being conducted to assess worker and firemen. A follow-up report will be submitted upon receipt of further information.</br>Tennessee State Event Report ID No: TN-15-167nessee State Event Report ID No: TN-15-167  +
14:20:00, 16 November 2015  +
51,540  +
15:53:00, 16 November 2015  +
14:20:00, 16 November 2015  +
The following was received from the State The following was received from the State of Tennessee via email:</br>A fire occurred in an off gas dust collector and particulate filtration system used for ventilation from a process providing oxidation of metal depleted uranium chips. Alarm engaged and fire suppression system engaged. The local fire department responded and reinforced suppression. The fire department departed by 11:20 AM. Initial indications indicate no releases to the environment based on visual indications and stack monitoring systems not alarming. Negative pressure to the building was maintained. Smears taken outside of the building and radiologically controlled area does not indicate any elevated activity outside of the building. Air samples are being pulled and analyzed for workplace and air effluent stacks. Bioassays were being conducted to assess worker and firemen. A follow-up report will be submitted upon receipt of further information.</br>Tennessee State Event Report ID No: TN-15-167nessee State Event Report ID No: TN-15-167  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 16 November 2015  +
S-01046  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
01:46:16, 2 March 2018  +
15:53:00, 16 November 2015  +
0.0646 d (1.55 hours, 0.00923 weeks, 0.00212 months)  +
14:20:00, 16 November 2015  +
Agreement State Report - Fire in an Off Gas Dust Collector  +