Browse wiki
Jump to navigation
Jump to search
The following report was received via e-ma … The following report was received via e-mail:</br>On October 1, 2015 the Agency was notified by the licensee's radiation safety officer that a source was disconnected and dropped into a vessel. (This was caused by) a shutter malfunction which occurred on October 1, 2015 at 0930 (CDT) on a nuclear gauge. The source is an Ohmart Model MDTS, Serial Number 8480GK, Cesium 137, 9.5 mCi source. The shutter malfunction occurred during a routine check of the shutter operation. This particular device utilizes a tape which is connected to the source. The tape allows the source to be lowered and raised inside a well within the vessel. During the routine shutter checks, the tape disconnected from the source. At this time, the source is located inside the well near its normal operational position. A radiation survey was conducted at areas which would contain general employee access. All radiation readings were at background level. This event did not cause any additional radiation exposure than normal day to day operations. The gauge manufacturer has been notified and will be on-site October 7, 2015 to repair the device. Updates will be provided in accordance with SA-300 guidelines.</br>Texas Incident: I-9342SA-300 guidelines.
Texas Incident: I-9342 +
14:30:00, 1 October 2015 +
51,437 +
15:26:00, 1 October 2015 +
14:30:00, 1 October 2015 +
The following report was received via e-ma … The following report was received via e-mail:</br>On October 1, 2015 the Agency was notified by the licensee's radiation safety officer that a source was disconnected and dropped into a vessel. (This was caused by) a shutter malfunction which occurred on October 1, 2015 at 0930 (CDT) on a nuclear gauge. The source is an Ohmart Model MDTS, Serial Number 8480GK, Cesium 137, 9.5 mCi source. The shutter malfunction occurred during a routine check of the shutter operation. This particular device utilizes a tape which is connected to the source. The tape allows the source to be lowered and raised inside a well within the vessel. During the routine shutter checks, the tape disconnected from the source. At this time, the source is located inside the well near its normal operational position. A radiation survey was conducted at areas which would contain general employee access. All radiation readings were at background level. This event did not cause any additional radiation exposure than normal day to day operations. The gauge manufacturer has been notified and will be on-site October 7, 2015 to repair the device. Updates will be provided in accordance with SA-300 guidelines.</br>Texas Incident: I-9342SA-300 guidelines.
Texas Incident: I-9342 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 1 October 2015 +
00243 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:17:11, 24 September 2017 +
15:26:00, 1 October 2015 +
0.0388 d (0.93 hours, 0.00554 weeks, 0.00127 months) +
14:30:00, 1 October 2015 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.