Browse wiki

Jump to navigation Jump to search
The gauge is a Kay-Ray Model 7063P, serialThe gauge is a Kay-Ray Model 7063P, serial number 8289 with a nominal source of 1 Curie of Cesium 137. The gauge is used for lime slurry density measurements in the Unit 1 Scrubber.</br>The malfunctioning shutter was discovered on June 6, 2015 during semiannual shutter checks as required by the license. The checks were completed today, and (the Radiation Safety Officer (RSO)) became aware of the issue as (the RSO) reviewed the documentation. Independent verification of the malfunction was made, it was found to not close. The cause of the malfunction is not known at this time.</br>The gauge is located approximately sixteen feet above the ground level and presents no unusual risk to plant personnel. No maintenance activities will be conducted on the pipe or elbow the gauge is attached to until the shutter has been repaired. All plant personnel have been notified of the issue and the requisite restriction.</br>(The RSO) contacted a properly licensed contractor to arrange for the repair to the shutter.</br>This gauge is normally open during plant operation.e is normally open during plant operation.  +
06:00:00, 10 June 2015  +
51,143  +
14:00:00, 10 June 2015  +
06:00:00, 10 June 2015  +
The gauge is a Kay-Ray Model 7063P, serialThe gauge is a Kay-Ray Model 7063P, serial number 8289 with a nominal source of 1 Curie of Cesium 137. The gauge is used for lime slurry density measurements in the Unit 1 Scrubber.</br>The malfunctioning shutter was discovered on June 6, 2015 during semiannual shutter checks as required by the license. The checks were completed today, and (the Radiation Safety Officer (RSO)) became aware of the issue as (the RSO) reviewed the documentation. Independent verification of the malfunction was made, it was found to not close. The cause of the malfunction is not known at this time.</br>The gauge is located approximately sixteen feet above the ground level and presents no unusual risk to plant personnel. No maintenance activities will be conducted on the pipe or elbow the gauge is attached to until the shutter has been repaired. All plant personnel have been notified of the issue and the requisite restriction.</br>(The RSO) contacted a properly licensed contractor to arrange for the repair to the shutter.</br>This gauge is normally open during plant operation.e is normally open during plant operation.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 10 June 2015  +
33-18224-01  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:17:38, 24 September 2017  +
14:00:00, 10 June 2015  +
0.333 d (8 hours, 0.0476 weeks, 0.011 months)  +
06:00:00, 10 June 2015  +
Density Gauge Shutter Stuck Open  +