At 1013 hours PDT on August 19, 2013 the R … At 1013 hours PDT on August 19, 2013 the Reactor Building Stack Radiation Monitor High Range Detector was declared nonfunctional due to increasing background noise. The Reactor Building Stack Radiation Monitor Intermediate Range Detector remains functional and shows no increase in effluent radioactivity.</br>To compensate for the loss of assessment capability due to the nonfunctioning radiation monitoring equipment, an additional Health Physics (HP) Technician trained to acquire offsite dose assessment information on offsite releases will be available. The additional personnel will be pre-staged in support of the Radiation Monitoring System outage and will be mobilized in accordance with guidance in the compensatory measure instructions.</br>This event is being reported as a loss of emergency assessment capability in accordance with 10 CFR 50.72(b)(3)(xiii). A follow-up notification will be made when the equipment has been returned to service.</br>The licensee will notify the NRC Resident Inspector.</br> * * * UPDATE FROM MICHAEL STODICK TO PETE SNYDER AT 2028 EDT ON 8/19/13 * * * </br>Initial investigation into the cause of the malfunction of the Reactor Building Stack Radiation Monitor High Range Detector revealed that the condition also affected the Reactor Building Stack Radiation Monitor Intermediate Range Detector. Therefore, this monitor has also been declared non-functional as of 1633 hours PDT on August 19, 2013. Compensatory measures remain in effect to provide emergency response capability for assessing and monitoring actual or potential offsite consequences of a radiological release through this pathway. Corrective actions are being pursued to restore the affected monitors to functional status.</br>The licensee notified the NRC Resident Inspector. Notified R4DO (Werner).</br>* * * UPDATE FROM MOT HEDGES TO HOWIE CROUCH AT 1236 EDT ON 8/21/13 * * *</br>The cause of the increased background noise for the Reactor Building Stack Radiation Monitor-High Range was due to failing cooling components for the instrumentation, resulting in increased electronic background noise in the instrumentation. There has been no change in the radiation levels at the plant.</br>The NRC Resident Inspector has been notified.</br>Notified R4DO (Werner).</br>* * * UPDATE FROM MOT HEDGES TO MARK ABRAMOVITZ ON 8/22/2013 AT 1630 EDT * * *</br>Repairs have been completed and both the Intermediate and High Range Reactor Building Stack Radiation Monitors have been returned to service. The licensee has notified the NRC Resident Inspector.</br>Notified the R4DO (Werner).ent Inspector.
Notified the R4DO (Werner).
17:13:00, 19 August 2013 +
49,290 +
17:23:00, 19 August 2013 +
17:13:00, 19 August 2013 +
At 1013 hours PDT on August 19, 2013 the R … At 1013 hours PDT on August 19, 2013 the Reactor Building Stack Radiation Monitor High Range Detector was declared nonfunctional due to increasing background noise. The Reactor Building Stack Radiation Monitor Intermediate Range Detector remains functional and shows no increase in effluent radioactivity.</br>To compensate for the loss of assessment capability due to the nonfunctioning radiation monitoring equipment, an additional Health Physics (HP) Technician trained to acquire offsite dose assessment information on offsite releases will be available. The additional personnel will be pre-staged in support of the Radiation Monitoring System outage and will be mobilized in accordance with guidance in the compensatory measure instructions.</br>This event is being reported as a loss of emergency assessment capability in accordance with 10 CFR 50.72(b)(3)(xiii). A follow-up notification will be made when the equipment has been returned to service.</br>The licensee will notify the NRC Resident Inspector.</br> * * * UPDATE FROM MICHAEL STODICK TO PETE SNYDER AT 2028 EDT ON 8/19/13 * * * </br>Initial investigation into the cause of the malfunction of the Reactor Building Stack Radiation Monitor High Range Detector revealed that the condition also affected the Reactor Building Stack Radiation Monitor Intermediate Range Detector. Therefore, this monitor has also been declared non-functional as of 1633 hours PDT on August 19, 2013. Compensatory measures remain in effect to provide emergency response capability for assessing and monitoring actual or potential offsite consequences of a radiological release through this pathway. Corrective actions are being pursued to restore the affected monitors to functional status.</br>The licensee notified the NRC Resident Inspector. Notified R4DO (Werner).</br>* * * UPDATE FROM MOT HEDGES TO HOWIE CROUCH AT 1236 EDT ON 8/21/13 * * *</br>The cause of the increased background noise for the Reactor Building Stack Radiation Monitor-High Range was due to failing cooling components for the instrumentation, resulting in increased electronic background noise in the instrumentation. There has been no change in the radiation levels at the plant.</br>The NRC Resident Inspector has been notified.</br>Notified R4DO (Werner).</br>* * * UPDATE FROM MOT HEDGES TO MARK ABRAMOVITZ ON 8/22/2013 AT 1630 EDT * * *</br>Repairs have been completed and both the Intermediate and High Range Reactor Building Stack Radiation Monitors have been returned to service. The licensee has notified the NRC Resident Inspector.</br>Notified the R4DO (Werner).ent Inspector.
Notified the R4DO (Werner).
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 22 August 2013 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:00:11, 2 March 2018 +
17:23:00, 19 August 2013 +
true +
false +
0.00708 d (0.17 hours, 0.00101 weeks, 2.32866e-4 months) +
17:13:00, 19 August 2013 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.