The following report was received from the … The following report was received from the Texas Department of State Health Services, Radiation Branch, via e-mail:</br>The licensee RSO reported that, during securing the source rack (on a pool irradiator), a tote on the conveyor became lodged against the rack mechanism causing it to halt before being completely secured. The maintenance manager and an operation technician were able to dislodge the tote without receiving any additional exposure. They manually moved the conveyor belt dislodging the tote and allowing the rack to continue to its secure position in the irradiator pool. The licensee will submit a complete report within 30 days.</br>(The Texas Radiation Branch classifies this report as a) 30.50(b)(2) event type involving equipment failure or disability to function as designed when equipment is required to be available and operable and no redundant equipment is available and operable, includes source disconnection and failure to retract source.</br>Texas Report I-9044ure to retract source.
Texas Report I-9044 +
06:00:00, 20 February 2013 +
48,774 +
17:01:00, 20 February 2013 +
06:00:00, 20 February 2013 +
The following report was received from the … The following report was received from the Texas Department of State Health Services, Radiation Branch, via e-mail:</br>The licensee RSO reported that, during securing the source rack (on a pool irradiator), a tote on the conveyor became lodged against the rack mechanism causing it to halt before being completely secured. The maintenance manager and an operation technician were able to dislodge the tote without receiving any additional exposure. They manually moved the conveyor belt dislodging the tote and allowing the rack to continue to its secure position in the irradiator pool. The licensee will submit a complete report within 30 days.</br>(The Texas Radiation Branch classifies this report as a) 30.50(b)(2) event type involving equipment failure or disability to function as designed when equipment is required to be available and operable and no redundant equipment is available and operable, includes source disconnection and failure to retract source.</br>Texas Report I-9044ure to retract source.
Texas Report I-9044 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 20 February 2013 +
L03851 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:23:02, 24 September 2017 +
17:01:00, 20 February 2013 +
0.459 d (11.02 hours, 0.0656 weeks, 0.0151 months) +
06:00:00, 20 February 2013 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.