Browse wiki

Jump to navigation Jump to search
At 1625 CST on 11-19-12, Electrical MainteAt 1625 CST on 11-19-12, Electrical Maintenance and Power Operations were in the process of changing a circuit breaker in the C-409 facility which supplies power to the C-409 Criticality Accident Alarm System (CAAS) Uninterruptable Power Supply (UPS). This UPS supplies power to the C-409 CAAS horns. Procedure CP2-CO-ON3031 was being utilized and the CAAS Horn Power UPS was being monitored continuously to maintain the CAAS operable. As soon as the breaker was opened it was identified that the UPS failed to throw over to battery power. At that point the breaker was re-closed and AC power restored to the CAAS horns. The time that AC power was off the CAAS horns was approximately 3-5 seconds. There were no fissile material operations in progress in the C-409 facility. This event is reportable as a 24 hour event in accordance with 10CFR76.120(c)(2)(i). This is an event in which equipment is disabled or fails to function as designed when: a.) the equipment is required by a TSR (Technical Safety Requirements) to prevent releases, prevent exposures to radiation and radioactive materials exceeding specified limits, mitigate the consequences of an accident, or restore this facility to a pre-established safe condition after an accident; b.) the equipment is required by a TSR to be available and operable and either should have been operating or should have operated on demand, and c.) no redundant equipment is available and operable to perform the required safety function.</br>The NRC Senior Resident Inspector has been notified of this event.Inspector has been notified of this event.  +
22:25:00, 19 November 2012  +
48,522  +
11:02:00, 20 November 2012  +
22:25:00, 19 November 2012  +
At 1625 CST on 11-19-12, Electrical MainteAt 1625 CST on 11-19-12, Electrical Maintenance and Power Operations were in the process of changing a circuit breaker in the C-409 facility which supplies power to the C-409 Criticality Accident Alarm System (CAAS) Uninterruptable Power Supply (UPS). This UPS supplies power to the C-409 CAAS horns. Procedure CP2-CO-ON3031 was being utilized and the CAAS Horn Power UPS was being monitored continuously to maintain the CAAS operable. As soon as the breaker was opened it was identified that the UPS failed to throw over to battery power. At that point the breaker was re-closed and AC power restored to the CAAS horns. The time that AC power was off the CAAS horns was approximately 3-5 seconds. There were no fissile material operations in progress in the C-409 facility. This event is reportable as a 24 hour event in accordance with 10CFR76.120(c)(2)(i). This is an event in which equipment is disabled or fails to function as designed when: a.) the equipment is required by a TSR (Technical Safety Requirements) to prevent releases, prevent exposures to radiation and radioactive materials exceeding specified limits, mitigate the consequences of an accident, or restore this facility to a pre-established safe condition after an accident; b.) the equipment is required by a TSR to be available and operable and either should have been operating or should have operated on demand, and c.) no redundant equipment is available and operable to perform the required safety function.</br>The NRC Senior Resident Inspector has been notified of this event.Inspector has been notified of this event.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
2.777778e-4 d (0.00667 hours, 3.968254e-5 weeks, 9.132e-6 months)  +
00:00:00, 20 November 2012  +
GDP-1  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:14:34, 24 November 2018  +
11:02:00, 20 November 2012  +
0.526 d (12.62 hours, 0.0751 weeks, 0.0173 months)  +
22:25:00, 19 November 2012  +
Uninterruptible Power Supply Safety Equipment Failure  +