Browse wiki
Jump to navigation
Jump to search
Name of the firm constructing or supplying … Name of the firm constructing or supplying the basic component which contains the deviation or fails to comply:</br>Engineered Products Department</br>PO Box 2138</br>Carlsbad, NM 88221</br>Description of the deviation or failure to comply which is being evaluated :</br>Undersized welds were identified on centrifuge T-column to base plate connectors which are still in construction. The welds do not comply with AWS 01.1 and are currently being evaluated for the potential to cause substantial safety hazards. An extent of condition is in progress to identify any further conditions and to provide weld dimensions to the design agent for engineering analysis. This analysis will determine the ability of the steelwork to perform per design requirements.</br>The date on which the information of suspect deviation defect or failure to comply was obtained:</br>24 August, 2011</br>The date on which the evaluation is expected to be complete:</br>23 November, 2011expected to be complete:
23 November, 2011 +
06:00:00, 24 August 2011 +
47,365 +
17:05:00, 21 October 2011 +
06:00:00, 24 August 2011 +
Name of the firm constructing or supplying … Name of the firm constructing or supplying the basic component which contains the deviation or fails to comply:</br>Engineered Products Department</br>PO Box 2138</br>Carlsbad, NM 88221</br>Description of the deviation or failure to comply which is being evaluated :</br>Undersized welds were identified on centrifuge T-column to base plate connectors which are still in construction. The welds do not comply with AWS 01.1 and are currently being evaluated for the potential to cause substantial safety hazards. An extent of condition is in progress to identify any further conditions and to provide weld dimensions to the design agent for engineering analysis. This analysis will determine the ability of the steelwork to perform per design requirements.</br>The date on which the information of suspect deviation defect or failure to comply was obtained:</br>24 August, 2011</br>The date on which the evaluation is expected to be complete:</br>23 November, 2011expected to be complete:
23 November, 2011 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 21 October 2011 +
SNM-2010 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:18:34, 24 November 2018 +
17:05:00, 21 October 2011 +
58.462 d (1,403.08 hours, 8.352 weeks, 1.922 months) +
06:00:00, 24 August 2011 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.