Browse wiki

Jump to navigation Jump to search
100  +
(This is a) historical condition previousl(This is a) historical condition previously reported in LER 2009-001 (that) should also have been reported in accordance with 10 CFR 50.72(b)(3)(v)(D).</br>Due to misapplication of Potter and Brumfield Rotary Relays, both operating Containment Air Cooler Fans were declared inoperable on October 13, 2009, and the fans switched from their normal fast speed alignment to the slow speed alignment used for accidents, which eliminated the relay issue and allowed them to be declared operable. This issue was reported in LER 2009-001 as an operation prohibited by the Technical Specifications on December 14, 2009. The fan control circuitry was modified to correct the condition. </br>Upon further review, this condition should have been reported per the requirements of 10 CFR 50.72(b)(3)(v)(D) due to both required Containment Air Cooler Fan trains being declared inoperable for the condition. A revision to LER 2009-001 will be submitted per 10 CFR 50.73(a)(2)(v)(D).</br>The NRC Senior Resident Inspector has been notified.nior Resident Inspector has been notified.  +
16:07:00, 13 October 2009  +
46,063  +
13:58:00, 1 July 2010  +
16:07:00, 13 October 2009  +
(This is a) historical condition previousl(This is a) historical condition previously reported in LER 2009-001 (that) should also have been reported in accordance with 10 CFR 50.72(b)(3)(v)(D).</br>Due to misapplication of Potter and Brumfield Rotary Relays, both operating Containment Air Cooler Fans were declared inoperable on October 13, 2009, and the fans switched from their normal fast speed alignment to the slow speed alignment used for accidents, which eliminated the relay issue and allowed them to be declared operable. This issue was reported in LER 2009-001 as an operation prohibited by the Technical Specifications on December 14, 2009. The fan control circuitry was modified to correct the condition. </br>Upon further review, this condition should have been reported per the requirements of 10 CFR 50.72(b)(3)(v)(D) due to both required Containment Air Cooler Fan trains being declared inoperable for the condition. A revision to LER 2009-001 will be submitted per 10 CFR 50.73(a)(2)(v)(D).</br>The NRC Senior Resident Inspector has been notified.nior Resident Inspector has been notified.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100  +
00:00:00, 1 July 2010  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:09:18, 2 March 2018  +
13:58:00, 1 July 2010  +
false  +
260.91 d (6,261.85 hours, 37.273 weeks, 8.577 months)  +
16:07:00, 13 October 2009  +
Historic Condition with Containment Cooler Fan Relays  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +