Browse wiki
Jump to navigation
Jump to search
100 +
A CARDOX release occurred in the Unit-1 ma … A CARDOX release occurred in the Unit-1 main turbine lube oil room and an Unusual Event was declared. The release resulted in an atmosphere immediately dangerous to life and health resulting in an Alert notification. No injuries resulted, however, the crane bay in the center of the turbine building was evacuated. Approximately 30% of the CARDOX storage tank was discharged due to a malfunctioning solenoid valve. This valve had recently been replaced.</br>The licensee notified the NRC Resident Inspector.</br>* * * UPDATE AT 1525 EDT ON 6/23/10 FROM TONY CHITWOOD TO S. SANDIN * * *</br>The licensee provided the following information as an update:</br>On June 23, 2010, at 1035 PDT, an accidental discharge of CARDOX into Unit 1 Main Lube Oil Reservoir Room occurred during testing. On June 23, at 1048 PDT, an Unusual Event was declared for DCPP Unit 1. On June 23, at 1056 PDT, an Alert was declared for DCPP Unit 1. The DCPP Unit 1 reactor remains at full power. No safety related equipment has been impacted. There were no injuries to personnel and no equipment damage. Offsite assistance was requested to assist in event response.</br>Pacific Gas and Electric Company issued the first press release at 1225 PDT on June 23, 2010. Further press releases will be issued as necessary until the event is terminated.</br>The licensee notified the NRC Resident Inspector." The licensee also informed state and local agencies. Notified R4DO (Pick).</br>* * * UPDATE AT 2028 EDT ON 6/23/10 FROM DAVID EFRON TO S. SANDIN * * * </br>The licensee has terminated the Alert at 1715 PDT based on restoring accessibility to all plant area.</br>The licensee will inform state/local agencies, the NRC Resident Inspector and issue a follow-up press release.</br>Notified R4DO (Pick), NRR EO (Cunningham), IRD (Morris), DHS (Inzer), FEMA (Hollis), DOE (Yates), USDA (Petrick), and HHS (Lee).OE (Yates), USDA (Petrick), and HHS (Lee). +
17:48:00, 23 June 2010 +
46,036 +
14:11:00, 23 June 2010 +
17:48:00, 23 June 2010 +
A CARDOX release occurred in the Unit-1 ma … A CARDOX release occurred in the Unit-1 main turbine lube oil room and an Unusual Event was declared. The release resulted in an atmosphere immediately dangerous to life and health resulting in an Alert notification. No injuries resulted, however, the crane bay in the center of the turbine building was evacuated. Approximately 30% of the CARDOX storage tank was discharged due to a malfunctioning solenoid valve. This valve had recently been replaced.</br>The licensee notified the NRC Resident Inspector.</br>* * * UPDATE AT 1525 EDT ON 6/23/10 FROM TONY CHITWOOD TO S. SANDIN * * *</br>The licensee provided the following information as an update:</br>On June 23, 2010, at 1035 PDT, an accidental discharge of CARDOX into Unit 1 Main Lube Oil Reservoir Room occurred during testing. On June 23, at 1048 PDT, an Unusual Event was declared for DCPP Unit 1. On June 23, at 1056 PDT, an Alert was declared for DCPP Unit 1. The DCPP Unit 1 reactor remains at full power. No safety related equipment has been impacted. There were no injuries to personnel and no equipment damage. Offsite assistance was requested to assist in event response.</br>Pacific Gas and Electric Company issued the first press release at 1225 PDT on June 23, 2010. Further press releases will be issued as necessary until the event is terminated.</br>The licensee notified the NRC Resident Inspector." The licensee also informed state and local agencies. Notified R4DO (Pick).</br>* * * UPDATE AT 2028 EDT ON 6/23/10 FROM DAVID EFRON TO S. SANDIN * * * </br>The licensee has terminated the Alert at 1715 PDT based on restoring accessibility to all plant area.</br>The licensee will inform state/local agencies, the NRC Resident Inspector and issue a follow-up press release.</br>Notified R4DO (Pick), NRR EO (Cunningham), IRD (Morris), DHS (Inzer), FEMA (Hollis), DOE (Yates), USDA (Petrick), and HHS (Lee).OE (Yates), USDA (Petrick), and HHS (Lee). +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 23 June 2010 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:09:22, 2 March 2018 +
14:11:00, 23 June 2010 +
true +
false +
-0.151 d (-3.62 hours, -0.0215 weeks, -0.00496 months) +
17:48:00, 23 June 2010 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.