A furnace in the Specialty Fuels Facility … A furnace in the Specialty Fuels Facility (SFF) was being tested in order to return it to operation. As part of the test, the airflow for the ventilation was checked to ensure that if the airflow decreased to a level below what was required per the Integrated Safety Analysis (ISA), then the appropriate furnace systems would automatically shutdown. During the test with hydrogen gas flowing into the furnace and therefore the ventilation system, the shutdown sequence shutdown the hydrogen flow when the flow was at 100%, but it did not shutdown the hydrogen flow when the flow was at 8%. There was no immediate risk or threat to the safety of workers or the public as a result of this event.</br>An evaluation is currently being performed.</br>BWXT is making this 24 hour report in accordance with 10 CFR 70.61, Appendix A (b)(1) - 'Any event or condition that results in the facility being in a state that was not analyzed, was improperly analyzed, or is different from that analyzed in the Integrated Safety Analysis, and which results in failure to meet the performance requirements of 70.61.'</br>The furnace is shutdown pending further investigation.</br>The licensee will notify the NRC Resident Inspector.</br>* * * UPDATE FROM CHERYL GOFF TO JOE O'HARA AT 1505 ON 01/14/09 * * * </br>On January 9, 2009 BWXT made event notification #44761 regarding a furnace in the Specialty Fuels Facility (SFF) which failed to perform the shutdown sequence for a given hydrogen flow level required per the Integrated Safety Analysis (ISA). The furnace was shutdown pending further investigation. As a result of the ongoing investigation supplemental information to this notification is being provided.</br>In reviewing the programming code for the furnace a note was detected related to the flow of Carbon Monoxide (CO). Specifically, the note allowed for the continuation of the flow of CO if the temperature in the furnace was above 1000 C. Simulation testing of the validity of this note was performed and the test proved that the gas would continue to flow until the temperature of the furnace reached a level below 1000 C.</br>An evaluation is currently being performed. The furnace continues to be shutdown pending further investigation.</br>The licensee informed the NRC Resident Inspector.</br>Notified R2DO(Rudisail), NMSS EO(Davis), and Fuels Group via e-mail.MSS EO(Davis), and Fuels Group via e-mail.
18:30:00, 9 January 2009 +
44,761 +
17:26:00, 9 January 2009 +
18:30:00, 9 January 2009 +
A furnace in the Specialty Fuels Facility … A furnace in the Specialty Fuels Facility (SFF) was being tested in order to return it to operation. As part of the test, the airflow for the ventilation was checked to ensure that if the airflow decreased to a level below what was required per the Integrated Safety Analysis (ISA), then the appropriate furnace systems would automatically shutdown. During the test with hydrogen gas flowing into the furnace and therefore the ventilation system, the shutdown sequence shutdown the hydrogen flow when the flow was at 100%, but it did not shutdown the hydrogen flow when the flow was at 8%. There was no immediate risk or threat to the safety of workers or the public as a result of this event.</br>An evaluation is currently being performed.</br>BWXT is making this 24 hour report in accordance with 10 CFR 70.61, Appendix A (b)(1) - 'Any event or condition that results in the facility being in a state that was not analyzed, was improperly analyzed, or is different from that analyzed in the Integrated Safety Analysis, and which results in failure to meet the performance requirements of 70.61.'</br>The furnace is shutdown pending further investigation.</br>The licensee will notify the NRC Resident Inspector.</br>* * * UPDATE FROM CHERYL GOFF TO JOE O'HARA AT 1505 ON 01/14/09 * * * </br>On January 9, 2009 BWXT made event notification #44761 regarding a furnace in the Specialty Fuels Facility (SFF) which failed to perform the shutdown sequence for a given hydrogen flow level required per the Integrated Safety Analysis (ISA). The furnace was shutdown pending further investigation. As a result of the ongoing investigation supplemental information to this notification is being provided.</br>In reviewing the programming code for the furnace a note was detected related to the flow of Carbon Monoxide (CO). Specifically, the note allowed for the continuation of the flow of CO if the temperature in the furnace was above 1000 C. Simulation testing of the validity of this note was performed and the test proved that the gas would continue to flow until the temperature of the furnace reached a level below 1000 C.</br>An evaluation is currently being performed. The furnace continues to be shutdown pending further investigation.</br>The licensee informed the NRC Resident Inspector.</br>Notified R2DO(Rudisail), NMSS EO(Davis), and Fuels Group via e-mail.MSS EO(Davis), and Fuels Group via e-mail.
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 14 January 2009 +
SNM-42 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
23:27:35, 24 November 2018 +
17:26:00, 9 January 2009 +
-0.0446 d (-1.07 hours, -0.00637 weeks, -0.00147 months) +
18:30:00, 9 January 2009 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.