Browse wiki

Jump to navigation Jump to search
The following information was reported by The following information was reported by facsimile. </br>The North Carolina Department of Environment and Natural Resources reported a damaged Troxler moisture density gage during construction activities in Reidsville, NC. The NC Radiation Protection Section dispatched a health physicist to the site, the health physicist secured the damaged gage on site and conducted radiation exposure surveys to access the status of the radioactive sources. All indications and surveys support that no radiological damage occurred to those workers involved and no damage was incurred to the environment. </br>Damage to the gage resulted in a potential loss of shielding. If the gage is mishandled the source rod will pull out. The gage was secured and the sliding block was closed.</br>Stakeholders and responsible parties were contacted and are arranging to have the gage appropriately transferred to the manufacturer for further evaluation. </br>Troxler Model # 3430, S/N 34504</br>Radiological Information:</br>Cs-137 10 milliCi S/N 77-1449</br>Am/Be 40 milliCi S/N 47-29961</br>Survey Results:</br>Background: 20 microR/hr</br>three inches from gage: 8 milliR/hr</br>After gage removed: 20 microR/hr (no indication of contamination)</br>NC Incident Report: 05-01 The license number was not provided.5-01 The license number was not provided.  +
12:25:00, 17 January 2005  +
41,343  +
16:50:00, 18 January 2005  +
12:25:00, 17 January 2005  +
The following information was reported by The following information was reported by facsimile. </br>The North Carolina Department of Environment and Natural Resources reported a damaged Troxler moisture density gage during construction activities in Reidsville, NC. The NC Radiation Protection Section dispatched a health physicist to the site, the health physicist secured the damaged gage on site and conducted radiation exposure surveys to access the status of the radioactive sources. All indications and surveys support that no radiological damage occurred to those workers involved and no damage was incurred to the environment. </br>Damage to the gage resulted in a potential loss of shielding. If the gage is mishandled the source rod will pull out. The gage was secured and the sliding block was closed.</br>Stakeholders and responsible parties were contacted and are arranging to have the gage appropriately transferred to the manufacturer for further evaluation. </br>Troxler Model # 3430, S/N 34504</br>Radiological Information:</br>Cs-137 10 milliCi S/N 77-1449</br>Am/Be 40 milliCi S/N 47-29961</br>Survey Results:</br>Background: 20 microR/hr</br>three inches from gage: 8 milliR/hr</br>After gage removed: 20 microR/hr (no indication of contamination)</br>NC Incident Report: 05-01 The license number was not provided.5-01 The license number was not provided.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 18 January 2005  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
22:41:46, 24 September 2017  +
16:50:00, 18 January 2005  +
1.184 d (28.42 hours, 0.169 weeks, 0.0389 months)  +
12:25:00, 17 January 2005  +
North Carolina Agreement State Report - Damaged Troxler  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.