Browse wiki

Jump to navigation Jump to search
100  +
This report is being made pursuant to 10CFThis report is being made pursuant to 10CFR50.72(b)(3)(v)(D), Event or Condition that could have prevented fulfillment of a Safety Function needed to mitigate the consequences of an Accident. During performance of scheduled surveillance test LIS-HP-310, Reactor Vessel High Water Level 8 (High Pressure Core Spray) HPCS Injection Valve Closure Instrument Channels A and B Functional Test, Instrument Maintenance personnel discovered one end of fuse 1B21A-F8 not fully seated. The other end of the fuse was fully seated, and was maintaining the un-clipped end in sufficient contact with the fuse holder to complete the circuit. Had the circuit been deenergized, a Control Room annunciator (1H13-P601 A404) would have alarmed, and High Pressure Core Spray (HPCS) automatic low level initiation circuits would have been disabled. The fuse was fully seated without incident.</br>Upon discovery of the unseated fuse, the initial operability determination concluded that adequate contact was maintained to keep the circuit OPERABLE. After followup evaluation by Engineering, it was determined that continued OPERABILITY could not be assured during a seismic event. Failure of this fuse would prevent automatic actuation of HPCS on reactor vessel level low 2; and would prevent automatic closure of the HPCS discharge valve 1E22-F004 on reactor vessel level high 8. This would prevent the HPCS system, a single train safety system, from performing its design function during a Loss of Coolant Accident subsequent to a seismic event. This is reportable as an 8 hour ENS notification." </br>The licensee informed the NRC Resident Inspector.ensee informed the NRC Resident Inspector.  +
07:10:00, 17 November 2003  +
40,325  +
09:35:00, 17 November 2003  +
07:10:00, 17 November 2003  +
This report is being made pursuant to 10CFThis report is being made pursuant to 10CFR50.72(b)(3)(v)(D), Event or Condition that could have prevented fulfillment of a Safety Function needed to mitigate the consequences of an Accident. During performance of scheduled surveillance test LIS-HP-310, Reactor Vessel High Water Level 8 (High Pressure Core Spray) HPCS Injection Valve Closure Instrument Channels A and B Functional Test, Instrument Maintenance personnel discovered one end of fuse 1B21A-F8 not fully seated. The other end of the fuse was fully seated, and was maintaining the un-clipped end in sufficient contact with the fuse holder to complete the circuit. Had the circuit been deenergized, a Control Room annunciator (1H13-P601 A404) would have alarmed, and High Pressure Core Spray (HPCS) automatic low level initiation circuits would have been disabled. The fuse was fully seated without incident.</br>Upon discovery of the unseated fuse, the initial operability determination concluded that adequate contact was maintained to keep the circuit OPERABLE. After followup evaluation by Engineering, it was determined that continued OPERABILITY could not be assured during a seismic event. Failure of this fuse would prevent automatic actuation of HPCS on reactor vessel level low 2; and would prevent automatic closure of the HPCS discharge valve 1E22-F004 on reactor vessel level high 8. This would prevent the HPCS system, a single train safety system, from performing its design function during a Loss of Coolant Accident subsequent to a seismic event. This is reportable as an 8 hour ENS notification." </br>The licensee informed the NRC Resident Inspector.ensee informed the NRC Resident Inspector.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
9.259259e-5 d (0.00222 hours, 1.322751e-5 weeks, 3.044e-6 months)  +
100  +
00:00:00, 17 November 2003  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
02:24:46, 2 March 2018  +
09:35:00, 17 November 2003  +
false  +
0.101 d (2.42 hours, 0.0144 weeks, 0.00331 months)  +
07:10:00, 17 November 2003  +
Event or Condition That Could Have Prevented Fulfillment of a Safety Function  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.
1  +