Browse wiki
Jump to navigation
Jump to search
The following is a summary of the informat … The following is a summary of the information provided by the Kansas Departments of Health and Environment (Department) via email:</br>On September 29, 2025, the University of Kansas Hospital Authority reported that a patient had received a seed for localized treatment of a tumor in their breast tissue. The seed was inserted on July 30, 2025. The patient returned the following day, very ill, was evaluated, and found to have an infection. The physician determined that surgery for removal of the seed would need to be delayed, and the seed could not be removed before October 2, 2025. The dose calculation shows that 5 rem total effective dose equivalent will be reached on October 2, 2025. This report is open and more details are expected following a reactive inspection by the Department. </br>Device: IsoAid Advantage I124A</br>Source: 200 uCi I-125</br>KS Report Number: KS2500011</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
05:00:00, 29 September 2025 +
57,960 +
12:47:00, 30 September 2025 +
05:00:00, 29 September 2025 +
The following is a summary of the informat … The following is a summary of the information provided by the Kansas Departments of Health and Environment (Department) via email:</br>On September 29, 2025, the University of Kansas Hospital Authority reported that a patient had received a seed for localized treatment of a tumor in their breast tissue. The seed was inserted on July 30, 2025. The patient returned the following day, very ill, was evaluated, and found to have an infection. The physician determined that surgery for removal of the seed would need to be delayed, and the seed could not be removed before October 2, 2025. The dose calculation shows that 5 rem total effective dose equivalent will be reached on October 2, 2025. This report is open and more details are expected following a reactive inspection by the Department. </br>Device: IsoAid Advantage I124A</br>Source: 200 uCi I-125</br>KS Report Number: KS2500011</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 30 September 2025 +
18-C801 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:04, 8 October 2025 +
12:47:00, 30 September 2025 +
1.324 d (31.78 hours, 0.189 weeks, 0.0435 months) +
05:00:00, 29 September 2025 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.