Browse wiki

Jump to navigation Jump to search
The following information was provided by The following information was provided by the Texas Department of State Health Services (the Department) via email: </br>On July 1, 2025, the Department received a notification from the licensee regarding a mechanical failure involving a level/density measurement gauge. The licensee reported that the failure was discovered on June 30, 2025. The affected gauge is a Berthold model LB 300 IRL Type I, containing a 500 millicurie cesium-137 sealed source. According to the licensee, the failure occurred when the cable connected to the source carrier broke, causing the source to become lodged within the thermowell inside the process vessel. The licensee stated that the vessel contains product, which is effectively shielding the source and limiting radiation levels outside the vessel. The licensee added that radiation surveys conducted on the vessel exterior indicated exposure levels of less than 2 milliroentgens per hour (mR/hr). There is no indication of elevated radiation risk to workers or members of the public. The licensee further stated that Berthold is scheduled to retrieve the source and repair the cable on July 2, 2025. Additional information will be provided in accordance with SA 300 Reporting requirements.</br>Texas Incident Number: 10207</br>NMED Number: TX250032cident Number: 10207 NMED Number: TX250032  +
05:00:00, 30 June 2025  +
57,792  +
15:38:00, 1 July 2025  +
05:00:00, 30 June 2025  +
The following information was provided by The following information was provided by the Texas Department of State Health Services (the Department) via email: </br>On July 1, 2025, the Department received a notification from the licensee regarding a mechanical failure involving a level/density measurement gauge. The licensee reported that the failure was discovered on June 30, 2025. The affected gauge is a Berthold model LB 300 IRL Type I, containing a 500 millicurie cesium-137 sealed source. According to the licensee, the failure occurred when the cable connected to the source carrier broke, causing the source to become lodged within the thermowell inside the process vessel. The licensee stated that the vessel contains product, which is effectively shielding the source and limiting radiation levels outside the vessel. The licensee added that radiation surveys conducted on the vessel exterior indicated exposure levels of less than 2 milliroentgens per hour (mR/hr). There is no indication of elevated radiation risk to workers or members of the public. The licensee further stated that Berthold is scheduled to retrieve the source and repair the cable on July 2, 2025. Additional information will be provided in accordance with SA 300 Reporting requirements.</br>Texas Incident Number: 10207</br>NMED Number: TX250032cident Number: 10207 NMED Number: TX250032  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 1 July 2025  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:03, 9 July 2025  +
15:38:00, 1 July 2025  +
1.443 d (34.63 hours, 0.206 weeks, 0.0474 months)  +
05:00:00, 30 June 2025  +
Equipment Failure  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.