Browse wiki

Jump to navigation Jump to search
The following information was provided by The following information was provided by the California Department of Public Health, Radiologic Health Branch via email:</br>A reciprocity licensee, Stronghold Inspection (TX license number L06918), was conducting industrial radiography at a laydown yard located on the Martinez Refining Company site (RML #3590). At about 0200 PDT, a pipe that was being radiographed rolled onto the guide tube of the exposure device (QSA Global 880 Delta, s/n D17238), crimping the guide tube and preventing the 2.73 TBq Ir-192 sealed source (QSA Model 8424-9, s/n 12805P) from retracting into its shielded position. The licensee reports that a perimeter spanning about 200 feet in radius was established. The exposure rate at the perimeter is less than 2 mR/hr and is under constant surveillance. The source is currently located in the collimator at the end of the guide tube. The licensee has requested the assistance of QSA's source retrieval team. Source retrieval is scheduled to begin upon arrival at approximately 1800 PDT. RHB inspectors arrived onsite at about 1000 PDT and will observe the operations until the source has been secured.</br>California 5010 number: 031425n secured. California 5010 number: 031425  +
09:00:00, 14 March 2025  +
57,608  +
20:26:00, 14 March 2025  +
09:00:00, 14 March 2025  +
The following information was provided by The following information was provided by the California Department of Public Health, Radiologic Health Branch via email:</br>A reciprocity licensee, Stronghold Inspection (TX license number L06918), was conducting industrial radiography at a laydown yard located on the Martinez Refining Company site (RML #3590). At about 0200 PDT, a pipe that was being radiographed rolled onto the guide tube of the exposure device (QSA Global 880 Delta, s/n D17238), crimping the guide tube and preventing the 2.73 TBq Ir-192 sealed source (QSA Model 8424-9, s/n 12805P) from retracting into its shielded position. The licensee reports that a perimeter spanning about 200 feet in radius was established. The exposure rate at the perimeter is less than 2 mR/hr and is under constant surveillance. The source is currently located in the collimator at the end of the guide tube. The licensee has requested the assistance of QSA's source retrieval team. Source retrieval is scheduled to begin upon arrival at approximately 1800 PDT. RHB inspectors arrived onsite at about 1000 PDT and will observe the operations until the source has been secured.</br>California 5010 number: 031425n secured. California 5010 number: 031425  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 14 March 2025  +
TX L06918  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:01:05, 24 March 2025  +
20:26:00, 14 March 2025  +
0.476 d (11.43 hours, 0.068 weeks, 0.0157 months)  +
09:00:00, 14 March 2025  +
Crimped Source Guide Tube  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.