The following report was received by the T … The following report was received by the Texas Department of State Health Services (the Department): </br>On 11/26/24, the Department was notified by the licensee of a malfunction that occurred with one of its cameras during an industrial radiography procedure. The licensee stated that a technician, while operating a SPEC 150 camera containing a 56 curie source of Ir-192, heard grinding noises during the crank-out process. The technician then retracted the source and conducted a source survey to confirm that it had returned to the shielded position. Upon inspection, the technician observed that the source was still extended at the end of the guide tube. The technician contacted the radiation safety officer (RSO), who responded to the scene, conducted an inspection, and was unable to determine if the source had become disconnected. The RSO subsequently covered the source with lead shielding and contacted the manufacturer who advised the licensee to transport the camera and source to the manufacturer for further examination and repair. </br>The licensee stated no members of the public were exposed to radiation because of the incident.</br>Additional information will be provided in accordance with SA-300.</br>Texas Incident Number: 10147</br>Texas NMED Number: 240046nt Number: 10147
Texas NMED Number: 240046 +
06:00:00, 26 November 2024 +
57,446 +
17:56:00, 26 November 2024 +
06:00:00, 26 November 2024 +
The following report was received by the T … The following report was received by the Texas Department of State Health Services (the Department): </br>On 11/26/24, the Department was notified by the licensee of a malfunction that occurred with one of its cameras during an industrial radiography procedure. The licensee stated that a technician, while operating a SPEC 150 camera containing a 56 curie source of Ir-192, heard grinding noises during the crank-out process. The technician then retracted the source and conducted a source survey to confirm that it had returned to the shielded position. Upon inspection, the technician observed that the source was still extended at the end of the guide tube. The technician contacted the radiation safety officer (RSO), who responded to the scene, conducted an inspection, and was unable to determine if the source had become disconnected. The RSO subsequently covered the source with lead shielding and contacted the manufacturer who advised the licensee to transport the camera and source to the manufacturer for further examination and repair. </br>The licensee stated no members of the public were exposed to radiation because of the incident.</br>Additional information will be provided in accordance with SA-300.</br>Texas Incident Number: 10147</br>Texas NMED Number: 240046nt Number: 10147
Texas NMED Number: 240046 +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 26 November 2024 +
06920 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:20:12, 5 December 2024 +
17:56:00, 26 November 2024 +
0.497 d (11.93 hours, 0.071 weeks, 0.0163 months) +
06:00:00, 26 November 2024 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.