The following information was provided by … The following information was provided by the licensee via email:</br>At 0146 CDT on June 7, 2024, River Bend Station (RBS) was operating at 100 percent power when a loss of control room envelope (CRE) was declared due to failing to meet Technical Specification (TS) 3.7.2, Surveillance Requirement (SR) 3.7.2.4, during surveillance testing. Mitigating actions were established which included the ability to issue potassium iodide to control room staff. With mitigating actions in place, the dose consequence to control room staff continued to be less than the regulatory limit of 5 rem total effective dose equivalent for the duration of a design basis event.</br>The CRE is considered a single train system at RBS, therefore, this event is being reported in accordance with 10 CFR 50.72(b)(3)(v)(D) as an event or condition that could have prevented the fulfillment of a safety function.</br>The NRC resident inspector has been notified.</br>The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:</br>The failed surveillance (SR 3.7.2.4) was for unfiltered air in-leakage greater than 300 cubic feet per minute.</br>* * * RETRACTION ON 08/05/2024 AT 1456 EDT FROM DARREN FARTHING TO ROBERT THOMPSON * * *</br>This event was initially reported under 10 CFR 50.72(b)(3)(v)(D) as an event or condition that could have prevented the fulfillment of a safety function. The licensee determined in a subsequent engineering evaluation of the conditions that existed at the time, that there was no adverse impact on the control room emergency ventilation system or the control room envelope (CRE) boundary's ability to perform its safety function. The CRE would not have been challenged to meet the regulatory limit of 5 rem total effective dose equivalent for the duration of a design basis event. Consequently, this condition is not reportable as an event or condition that could have prevented the fulfillment of a safety function.</br>The NRC resident inspector has been notified.</br>Notified R4DO (Vossmar).as been notified.
Notified R4DO (Vossmar).
06:46:00, 7 June 2024 +
15:10:00, 30 July 2024 +
06:46:00, 7 June 2024 +
The following information was provided by … The following information was provided by the licensee via email:</br>At 0146 CDT on June 7, 2024, River Bend Station (RBS) was operating at 100 percent power when a loss of control room envelope (CRE) was declared due to failing to meet Technical Specification (TS) 3.7.2, Surveillance Requirement (SR) 3.7.2.4, during surveillance testing. Mitigating actions were established which included the ability to issue potassium iodide to control room staff. With mitigating actions in place, the dose consequence to control room staff continued to be less than the regulatory limit of 5 rem total effective dose equivalent for the duration of a design basis event.</br>The CRE is considered a single train system at RBS, therefore, this event is being reported in accordance with 10 CFR 50.72(b)(3)(v)(D) as an event or condition that could have prevented the fulfillment of a safety function.</br>The NRC resident inspector has been notified.</br>The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:</br>The failed surveillance (SR 3.7.2.4) was for unfiltered air in-leakage greater than 300 cubic feet per minute.</br>* * * RETRACTION ON 08/05/2024 AT 1456 EDT FROM DARREN FARTHING TO ROBERT THOMPSON * * *</br>This event was initially reported under 10 CFR 50.72(b)(3)(v)(D) as an event or condition that could have prevented the fulfillment of a safety function. The licensee determined in a subsequent engineering evaluation of the conditions that existed at the time, that there was no adverse impact on the control room emergency ventilation system or the control room envelope (CRE) boundary's ability to perform its safety function. The CRE would not have been challenged to meet the regulatory limit of 5 rem total effective dose equivalent for the duration of a design basis event. Consequently, this condition is not reportable as an event or condition that could have prevented the fulfillment of a safety function.</br>The NRC resident inspector has been notified.</br>Notified R4DO (Vossmar).as been notified.
Notified R4DO (Vossmar).
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
100 +
00:00:00, 5 August 2024 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:20:06, 6 August 2024 +
15:10:00, 30 July 2024 +
true +
false +
53.35 d (1,280.4 hours, 7.621 weeks, 1.754 months) +
06:46:00, 7 June 2024 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.