The following report summary was received The following report summary was received by email from Virginia Radioactive Materials Program (VRMP):</br>On September 29, 2023, at approximately 0930 EDT, a Troxler moisture density gauge (model number: 3430, serial number: 32732, 8 mCi Cs-137, 40 mCi Am-241:Be) was struck by a bulldozer while the rod was extended out into the soil for measurements. The area was secured. The gauge was left in place so that the source would remain shielded by the soil and the radiation safety officer (RSO) was notified. The impact cracked the plastic housing and significantly bent the source rod handle above the gauge. The RSO verified that the source rod below the gauge was still intact. They were unable to get the source to retract. With the source inserted back into the soil, survey readings were obtained by the licensee as follows: 1 mR/hr on top of the gauge on contact; @ 5 ft away to the side 0.1 mR/hr. </br>According to the RSO, no public exposure occurred. The licensee has fitted a lead pig (lead shielded container) around the source for transport to a licensed nuclear gauge service company.</br>Virginia Event Report ID Number: VA230002 Virginia Event Report ID Number: VA230002  +
13:30:00, 29 September 2023  +
56,767  +
18:43:00, 29 September 2023  +
13:30:00, 29 September 2023  +
The following report summary was received The following report summary was received by email from Virginia Radioactive Materials Program (VRMP):</br>On September 29, 2023, at approximately 0930 EDT, a Troxler moisture density gauge (model number: 3430, serial number: 32732, 8 mCi Cs-137, 40 mCi Am-241:Be) was struck by a bulldozer while the rod was extended out into the soil for measurements. The area was secured. The gauge was left in place so that the source would remain shielded by the soil and the radiation safety officer (RSO) was notified. The impact cracked the plastic housing and significantly bent the source rod handle above the gauge. The RSO verified that the source rod below the gauge was still intact. They were unable to get the source to retract. With the source inserted back into the soil, survey readings were obtained by the licensee as follows: 1 mR/hr on top of the gauge on contact; @ 5 ft away to the side 0.1 mR/hr. </br>According to the RSO, no public exposure occurred. The licensee has fitted a lead pig (lead shielded container) around the source for transport to a licensed nuclear gauge service company.</br>Virginia Event Report ID Number: VA230002 Virginia Event Report ID Number: VA230002  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 2 October 2023  +
770-314-5  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:30:13, 10 October 2023  +
18:43:00, 29 September 2023  +
0.218 d (5.22 hours, 0.0311 weeks, 0.00715 months)  +
13:30:00, 29 September 2023  +
Damaged Moisture Density Gauge  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.