The following was received from the Colora … The following was received from the Colorado Department of Public Health and Environment via email: </br>The Radiation Safety Officer (RSO) reported at 1530 MDT on 9/5/23 that at about 1300 MDT on 9/5/23, a nuclear medicine technologist administered 206.7 mCi of Lu-177 PSMA (Pluvicto) to a patient, however the prescribed dosage on the written directive was only 160 mCi. The total dose delivered differed from the prescribed dose by 29 percent exceeding the threshold of 20 percent. The RSO indicated that the technician did not follow the written directive to verify the dose before injection because this type of treatment usually requires 200 mCi. At 1906 MDT on 9/5/23, the RSO provided a dose calculation that indicated the delivered dose differs from the prescribed dose by 0.49 Sv effective dose equivalent (more than the 0.05 Sv threshold) and 0.5-3.5 Sv to multiple organs (more than the 0.5 Sv threshold). A written report is required within 15 days of September 5, 2023.</br>Colorado Event Report ID No.: CO230028 </br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
19:00:00, 5 September 2023 +
56,717 +
11:01:00, 6 September 2023 +
19:00:00, 5 September 2023 +
The following was received from the Colora … The following was received from the Colorado Department of Public Health and Environment via email: </br>The Radiation Safety Officer (RSO) reported at 1530 MDT on 9/5/23 that at about 1300 MDT on 9/5/23, a nuclear medicine technologist administered 206.7 mCi of Lu-177 PSMA (Pluvicto) to a patient, however the prescribed dosage on the written directive was only 160 mCi. The total dose delivered differed from the prescribed dose by 29 percent exceeding the threshold of 20 percent. The RSO indicated that the technician did not follow the written directive to verify the dose before injection because this type of treatment usually requires 200 mCi. At 1906 MDT on 9/5/23, the RSO provided a dose calculation that indicated the delivered dose differs from the prescribed dose by 0.49 Sv effective dose equivalent (more than the 0.05 Sv threshold) and 0.5-3.5 Sv to multiple organs (more than the 0.5 Sv threshold). A written report is required within 15 days of September 5, 2023.</br>Colorado Event Report ID No.: CO230028 </br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient. +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 6 September 2023 +
CO 828-01 +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
11:30:10, 14 September 2023 +
11:01:00, 6 September 2023 +
0.668 d (16.02 hours, 0.0954 weeks, 0.0219 months) +
19:00:00, 5 September 2023 +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.