The following information was provided by The following information was provided by West Virginia University Hospital via telephone and email:</br>It was determined on 8/21/2023, that during a Y-90 (yttrium-90) Thera Sphere treatment performed on 8/17/2023, the delivered dose differed from the prescribed dose by more than 20 percent. The prescribed activity was 101.5 mCi and the administered activity was 3.4 mCi.</br>At the start of the infusion the authorized user (AU) was unable to deliver the microspheres due to a blood clot in the microcatheter. The AU then decided to abort the infusion and reschedule instead of chancing potential contamination that could occur by changing out the microcatheter.</br>The AU had completed the pre-treatment safety checklist with no issues. The AU has made the notification to the referring physician.</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.</br>* * * RETRACTION ON NOVEMBER 7, 2023, AT 1207 EST FROM WEST VIRGINIA UNIVERSITY HOSPITAL TO KAREN COTTON * * *</br>It was determined that the dose of yttrium-90 Thera Spheres was not delivered according to the written directive due to an emergent patient condition. Therefore, the incident does not qualify as a reportable medical event. </br>The patient's blood formed a clot within the microcatheter which prevented the passage of Y-90 microspheres. At the onset of administration, the Authorized User (AU) encountered significant resistance in the microcatheter, and they could not flush forward. When troubleshooting the delivery set, the AU visually identified the blood clot within the microcatheter. After several unsuccessful attempts to clear the blood clot, and in consultation with representatives from Boston Scientific, the AU decided to terminate the procedure. On September 1st, the Y-90 prescribed activity, as stated on the written directive, was successfully administered to the patient's hepatic artery. There were no adverse effects to the patient because of the underdose incident. The details of this incident were discussed with NRC inspectors who were on site for a reactive inspection. During those discussions it was concluded that since the patient's blood clotted within the microcatheter, the inability to complete the administration was due to an emergent patient condition. </br>The blood clot within the microcatheter was confirmed by an analysis of the delivery set performed by Boston Scientific's Product Analysis Team.</br>Notified: R1DO (Elise), NMSS Events Notification (E-mail)(Elise), NMSS Events Notification (E-mail)  
04:00:00, 17 August 2023  +
56,686  +
15:16:00, 21 August 2023  +
04:00:00, 17 August 2023  +
The following information was provided by The following information was provided by West Virginia University Hospital via telephone and email:</br>It was determined on 8/21/2023, that during a Y-90 (yttrium-90) Thera Sphere treatment performed on 8/17/2023, the delivered dose differed from the prescribed dose by more than 20 percent. The prescribed activity was 101.5 mCi and the administered activity was 3.4 mCi.</br>At the start of the infusion the authorized user (AU) was unable to deliver the microspheres due to a blood clot in the microcatheter. The AU then decided to abort the infusion and reschedule instead of chancing potential contamination that could occur by changing out the microcatheter.</br>The AU had completed the pre-treatment safety checklist with no issues. The AU has made the notification to the referring physician.</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.</br>* * * RETRACTION ON NOVEMBER 7, 2023, AT 1207 EST FROM WEST VIRGINIA UNIVERSITY HOSPITAL TO KAREN COTTON * * *</br>It was determined that the dose of yttrium-90 Thera Spheres was not delivered according to the written directive due to an emergent patient condition. Therefore, the incident does not qualify as a reportable medical event. </br>The patient's blood formed a clot within the microcatheter which prevented the passage of Y-90 microspheres. At the onset of administration, the Authorized User (AU) encountered significant resistance in the microcatheter, and they could not flush forward. When troubleshooting the delivery set, the AU visually identified the blood clot within the microcatheter. After several unsuccessful attempts to clear the blood clot, and in consultation with representatives from Boston Scientific, the AU decided to terminate the procedure. On September 1st, the Y-90 prescribed activity, as stated on the written directive, was successfully administered to the patient's hepatic artery. There were no adverse effects to the patient because of the underdose incident. The details of this incident were discussed with NRC inspectors who were on site for a reactive inspection. During those discussions it was concluded that since the patient's blood clotted within the microcatheter, the inability to complete the administration was due to an emergent patient condition. </br>The blood clot within the microcatheter was confirmed by an analysis of the delivery set performed by Boston Scientific's Product Analysis Team.</br>Notified: R1DO (Elise), NMSS Events Notification (E-mail)(Elise), NMSS Events Notification (E-mail)  
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 7 November 2023  +
47-23066-02  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:30:03, 8 November 2023  +
15:16:00, 21 August 2023  +
4.47 d (107.27 hours, 0.639 weeks, 0.147 months)  +
true  +
04:00:00, 17 August 2023  +
Medical Event - Patient Underdose  +