Browse wiki

Jump to navigation Jump to search
The following information was provided by The following information was provided by the Wisconsin Radiation Protection Section via email:</br>On February 10, 2023, the licensee reported a medical event which had occurred the previous day. A patient was being treated with a high dose rate remote after loader unit and the fraction required 17 needles. After the first 15 needles had been treated, the licensee noticed that the patient's needles had been pulled out approximately 2 cm from where they had been placed due to unexpected movement of the patient's bed. The licensee has not yet determined how the patient's bed moved, as the patient was sedated during treatment. Needles 16 and 17 were re-inserted and the dose to those needles was delivered as intended. The authorized user had prescribed 13.5 Gy to the treatment site for this fraction, and the licensee estimates that only 30 percent of the treatment volume received the prescribed dose. The referring physician and the patient's family have been notified.</br>Event Report ID No: WI230001</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient.  +
06:00:00, 10 February 2023  +
56,349  +
16:33:00, 10 February 2023  +
06:00:00, 10 February 2023  +
The following information was provided by The following information was provided by the Wisconsin Radiation Protection Section via email:</br>On February 10, 2023, the licensee reported a medical event which had occurred the previous day. A patient was being treated with a high dose rate remote after loader unit and the fraction required 17 needles. After the first 15 needles had been treated, the licensee noticed that the patient's needles had been pulled out approximately 2 cm from where they had been placed due to unexpected movement of the patient's bed. The licensee has not yet determined how the patient's bed moved, as the patient was sedated during treatment. Needles 16 and 17 were re-inserted and the dose to those needles was delivered as intended. The authorized user had prescribed 13.5 Gy to the treatment site for this fraction, and the licensee estimates that only 30 percent of the treatment volume received the prescribed dose. The referring physician and the patient's family have been notified.</br>Event Report ID No: WI230001</br>A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.necessarily result in harm to the patient.  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:00:00, 10 February 2023  +
025-1323-01  +
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
12:30:11, 21 February 2023  +
16:33:00, 10 February 2023  +
0.44 d (10.55 hours, 0.0628 weeks, 0.0145 months)  +
06:00:00, 10 February 2023  +
Patient Underdose  +
URL"URL" is a <a href="/Special:Types/URL" title="Special:Types/URL">type</a> and predefined property provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a> to represent URI/URL values.